2.3.4
Temperature Multiplexer Card (TMC)
Figure 2-4. Certification label for the Temperature Multiplexer Card 
(TMC).
The Temperature Multiplexer Card (TMC) is mounted within the 
flameproof enclosure. It is used for connecting up to 6 temperature 
sensors to the REX 3900 gauge.
The following information is provided as part of the label of the TMC:
Name and address of the manufacturer 
(Rosemount Tank Radar AB)
CE Conformity Marking:
Year of construction
Marking for explosion protection:
[Ex ia] IIC (Ga) (-40 °C 
Ta +85 °C)
Baseefa(2001) ATEX EC-Type Examination number: 
Baseefa03ATEX0050U
Schedule of Limitations
The Temperature Multiplexer Card must be housed within an 
enclosure which provides a degree of protection of at least IP20.
The 0V connections must be interconnected and connected to an 
I.S. earth point in accordance with EN60079-14 12.2.4., when the 
component is installed within an assembly.
The arrangements for the connections to non-hazardous area and 
hazardous area external circuits must comply with the require-
ments of Clause 6.3 of EN 50020:2002.
Note!
For electrical (I.S.) parameters refer to the appended EC-Type 
Examination Certificate Baseefa03ATEX0050U.