GAS SUPPLY
The gas line can be routed either through the floor or wall. The gas 
line opening should be made at this time. Location of the opening 
will be determined by the position of floor joists and the valve and 
union used for servicing.
Gas Supply 
Check all local codes for requirements, especially for the size and 
type of gas supply line required.
Note: Never use plastic pipe. Check to confirm whether your local 
codes allow copper tubing or galvanized.
Note: Since some municipalities have additional local codes, it is 
always best to consult your local authority and installation code.
GAS INLET
IN BOTTOM
OF HEATER
VIEW FROM TOP OF HEATER
1 11/16” (43mm)
TO WALL
3 9/16”
(90mm)
WALL
Dimensions Apply to SR-6, SR-10, SR-18
Figure 1
Installing a New Main Gas Cock 
Each appliance should have its own manual gas cock.
A manual main gas cock should be located in the vicinity of the 
unit. Where none exists, or where its size or location is not ad-
equate, contact your local authorized installer for installation or 
relocation.
Compounds used on threaded joints of gas piping shall be resistant 
to the action of liquefied petroleum gases. The gas lines must be 
checked for leaks by the installer. This should be done with a soap 
solution watching for bubbles on all exposed connections, and if 
unexposed, a pressure test should be made. 
Never use an exposed flame to check for leaks. Appliance must be 
disconnected from piping at inlet of control valve and pipe capped 
or plugged for pressure test. Never pressure test with appliance 
connected; control valve will sustain damage!
A gas valve and ground joint union should be installed in the gas 
line upstream of the gas control to aid in servicing. It is required 
by the National Fuel Gas Code that a drip line be installed near 
the gas inlet. This should consist of a vertical length of pipe tee 
connected into the gas line that is capped on the bottom in which 
condensation and foreign particles may collect.
Figure 2
Method of Installing a Tee Fitting Sediment Trap (Figure 2)
The use of the following gas connectors is recommended:
—  ANS Z21.24 Appliance Connectors of Corrugated Metal Tub-
ing and Fittings
—  ANS  Z21.45 Assembled  Flexible Appliance  Connectors  of 
Other Than All-Metal Construction
The above connectors may be used if acceptable by the authority 
having jurisdiction.
Pressure Testing of the Gas Supply System
1.  To check the inlet pressure to the gas valve, a 1/8" (3mm) N.P.T. 
plugged tapping, accessible for test gauge connection, must be 
placed immediately upstream of the gas supply connection to 
the appliance.
2.  The appliance and its appliance main gas valve must be discon-
nected from the gas supply piping system during any pressure 
testing of that system at test pressures in excess of 1/2 psig (3.5 
kPa).
3.  The appliance must be isolated from the gas supply piping sys-
tem by closing its equipment shutoff valve during any pressure 
testing of the gas supply piping system at test pressures equal 
to or less than 1/2 psig (3.5 kPa).
Attention! If one of the above procedures results in pressures in 
excess of 1/2 psig (14" w.c.) (3.5 kPa) on the appliance gas valve, 
it will result in a hazardous condition.
Checking Manifold Pressure
Natural gas will have a manifold pressure of approximately 6.0" 
w.c. (1.49kPa) at the pressure regulator outlet with the inlet pressure 
to the pressure regulator from a minimum of 7.0" w.c. (1.743kPa) 
for the purpose of input adjustment to a maximum of 10.5" w.c. 
(2.615kPa).   Propane/LP gas will have a manifold pressure ap-
proximately 10.0" w.c. (2.49kPa) at the pressure regulator outlet 
with the inlet pressure to the pressure regulator from a minimum 
of 11.0" w.c. (2.739kPa) for the purpose of input adjustment to a 
maximum of 13.0" w.c. (3.237kPa). 
A test gage connection is located downstream of the gas appliance 
pressure regulator for measuring gas pressure. The connection is a 
1/8 inch (3mm) N.P.T. plugged tapping.
Recommended Gas Pipe Diameter
Pipe Length
Schedule 40 Pipe
Inside Diameter
Tubing, Type L 
Outside Diameter
Nat.
L.P.
Nat.
L.P.
0-10 feet
0-3 meters
1/2”
12.7mm
3/8”
9.5mm
1/2”
12.7mm
3/8”
9.5mm
10-40 feet
4-12 meters
1/2”
12.7mm
1/2”
12.7mm
5/8”
15.9mm
1/2”
12.7mm
40-100 feet
13-30 meters
1/2”
12.7mm
1/2”
12.7mm
3/4”
19mm
1/2”
12.7mm
100-150 feet
31-46 meters
3/4”
19mm
1/2”
12.7mm
7/8”
22.2mm
3/4”
19mm