Emerson 308014EN Manuel D’Utilisation

Page de 166
Rosemount Tank Radar REX
Chapter 14 Technical Data
14-2
Installation Manual
308014EN, Edition 4
May 2013
Field bus (Standard)
TRL/2 Bus (FSK, half duplex, two 
wires, galvanically isolated, 4800 
Baud, Modbus based).
Field bus (Optional) 
Profibus
 DP.
RS 485 Modbus.
Tiway
 (only one relay available, 
analog output not available).
Enraf
 GPU (requires special field 
bus modem, EBM).
Varec
 (only one relay available, 
analog output not available).
L&J
 (only one relay available, 
analog output not available).
Whessoe
 (only one relay 
available, analog output not 
available).
GPE
 (only one relay available, 
analog output not available).
Sakura
 (only one relay available, 
analog output not available).
Foundation
 Fieldbus H1, IS.
(For more information please 
contact your sales representative)
14.1.1
Analog Inputs
Accuracy
± 20 μA
Input range
4-20 mA
Update rate
0.5 Hz
Low alarm level
< 3.8 mA, configurable
High Alrm Level
> 20.7 mA, configurable
U
max
 from TIC
25.2 V
I
max
 from TIC
96 mA
P
max
 from TIC
0.6 W
Available voltage
13.7 V (at 20 mA)