Emerson 308014EN Manuel D’Utilisation

Page de 166
10-1
Rosemount Tank Radar REX
Chapter 10 Mechanical Installation
Installation Manual
308014EN, Edition 4
May 2013
10. Mechanical Installation
To achieve precise and trouble free measurement, it is very important to 
mount the Radar Tank Gauge correctly on the tank. 
Please note that if an ullage plug is required, it has to be installed 
separately as there is no ullage plug on the Horn Antenna Gauge or the 
Parabolic Antenna Gauge. 
Note!
Please see the installation drawings for more information. There is a list 
of drawings in chapter 13. 
10.1 Mounting a Horn Antenna Gauge
The Horn Antenna Gauge must be installed so that there are no pipes or 
other obstacles that could prevent the radar beam to reach the bottom 
unobstructed. Please refer also to the mechanical installation drawing for 
more information on the installation requirements of the Horn Antenna 
Gauge and requirements on service space. 
10.1.1 Installation Requirements
Maximum height of socket is 330 mm. 
Figure 10-1. Installation requirements for Horn Antenna Gauge.
Socket height 
maximum 330 mm
Note! 
Levels closer than 
approximately 850 mm from the 
flange, cannot be measured 
with the highest accuracy.
3920_SocketReqmts.eps
Note!
For best performance the cone 
should end below the socket