26
1F95-391
Press TIME 
FWD
 and TIME 
BACK
 at the same time to enter the configuration menu. Press
TIME 
FWD
 until you get to °C then press the 
 or 
 arrow to select °F, press
PROGRAM 
RUN
 to return to normal operation.
Press PROGRAM 
RUN
  to make certain the thermostat is in the run program mode, then
to bypass the program and operate the thermostat manually press the MODE 
SYSTEM
 
button
to select Heat or Cool (whichever you prefer) and press 
HOLD
. Use the TEMP 
 
or
TEMP 
 
buttons to set the thermostat on the temperature you want. The temperature
setting you choose will be held until you manually change it using the TEMP 
 
or
TEMP 
 
buttons. The thermostat will remain in the HOLD mode when you change
temperature and maintain whatever temperature you set. If you decide to return to the
program, press PROGRAM 
RUN
 to cancel the hold feature.
FAQs
1. My thermostat is reading
Celsius. How do I change it
to Fahrenheit?
2. How do I bypass (not
use) the program?
Humidifier Control
and Monitoring
When the humidity button is pressed
while in the run mode and in the HEAT
position, the actual humidity will be
displayed on the left side of the
display. HUMD is displayed above
the actual humidity. The humidity set
point is displayed on the right side of
the display.  
 or 
 button
may be pressed to modify the humidity
set point (range 5 to 50). Maximum
displayed humidity is 97% RH and
minimum displayed humidity is 2%
RH. If the heating system is operating
and there is a demand for humidity,
then the humidifier will operate. If the
demand for humidity is not satisfied
for ten consecutive heat cycle
operations, the display will show the
word HUMD for one second and the
word MX for one second signaling
maximum possible humidity is
reached.