Emerson 1F97-391 Manuel D’Utilisation

Page de 52
18
Step
Press Button(s)
Displayed (Factory Default)
Press          or          to select:           
COMMENTS
1
EMR
(ON)
OFF
2
SET CYCL HEAT
(05)
02 - 40
Adjusts heat anticipation value (2 through 40)
See page 20
3
SET CYCL COOL
(12)
09 - 40
4
 COOL FAN DELA OFF
(01)
01 - 127
5
 COOL FAN DELA ON
(04)
01 - 05
6
 COMP LOCK
(OFF)
ON
7
 SYSTEM
(HEAT-OFF-COOL-AUTO)
HEAT-OFF,
COOL-OFF,
HEAT-OFF-COOL
Selects system switch choices for heat only,
cool only, heat/cool or automatic changeover
See page 21
Selects EMR option ON or OFF
See page 32
Adjusts cool anticipation value (9 through 40)
See page 20
Adjusts cool fan-off delay (1 through 127 sec.)
See page 20
Selects compressor lockout ON or OFF (see NOTE)
See page 21
Adjusts cool fan-on delay (1 through 5 sec.)
See page 20
TIME          
FWD
TIME          
FWD
TIME          
FWD
TIME          
FWD
TIME          
FWD
TIME          
FWD
TIME          
FWD
TIME          
BACK
CONFIGURA
CONFIGURA
CONFIGURA
CONFIGURA
CONFIGURATION MENU
TION MENU
TION MENU
TION MENU
TION MENU
The configuration menu allows you to set thermostat operating characteristics to your system or personal requirements.
To enter the menu, press TIME 
FWD
 and TIME 
BACK
 once at the same time. Press TIME 
FWD
 to advance through the
menu options. Press 
 
 arrow keys to change options. Either the installer or the operator may change shaded
options. We recommend that other options be set by the installer.