Multiquip MQ- D206H Manuel D’Utilisation

Page de 70
MQ-D206H DIAPHRAGM PUMP — PARTS  MANUAL— REV. #0 (12/15/03) — PAGE 19
MQ-D206H — INITIAL START-UP (ENGINE)
8. Before the pump is placed into operation, run the engine for
several minutes.  Check for  fuel leaks, and noises that would
associate with a lose component.
9.
To begin pumping, place the throttle lever (Figure 15) in the
"RUN" position.
Figure 14. Choke Lever (Closed)
Figure 15. Throttle Lever (Run)
Stopping The Engine
Normal Shutdown
1. Move the throttle lever  to the  IDLE position  (Figure 16) and
run the engine for three minutes at low speed.
Figure 16. Throttle Lever (Idle)
2. After the engine 
cools, turn the engine ON/OFF switch to the
OFF” position (Figure 17).
3. Place the 
fuel shut-off lever  (Figure 18)  in the ”OFF
position.
Figure 17.  Engine ON/OFF Switch (OFF)
Figure 18. Fuel Valve Lever (OFF)
Emergency Showdown
1. Move the throttle lever quickly to the 
“IDLE”  position, and
place the engine ON/OFF switch in the “OFF”  position.
NOTE
Pump speed can be 
regulated with
the engine throttle control from full
volume, 65 strokes per pinute, to
about 40 strokes per minute for
lesser volume seepage.Smoothest
operation can be determined by trying to pump at several speeds.
Limit maximum speed to 65 strokes per minute of the diaphragm
(2,800 RPM engine speed).
7. If the engine has started, slowly return the choke lever
(Figure 14 ) to the “CLOSED position. If the engine has not
started repeat steps 1 through 6.