Multiquip cx400 Manuel D’Utilisation

Page de 34
page 20 — cx400/px400 Sub. pump • operation and partS manual — rev. #1 (12/03/10) 
 OperatiOn
turning on the pump
If all of the pump's electrical requirements have been met, 
place the circuit breaker or power ON/OFF switch in the 
on position.
The CB3 control box has an operation switch  located on the 
front cover. This switch has 3 positions, 
automanual 
and 
oFF.  The auto position allows the pump to run in 
an un-attended mode. 
The 
manual position will let the pump run without the float 
switches controlling the pump. When in the manual mode 
be careful not to let the pump run dry. Severe damage to 
the pump may occur if it is allowed to run dry. 
never let 
the pump run dry.
manual operation
1.  For manual operation of the pump, place the 3-position 
operation switch (Figure Figure 13) on the control box 
in the 
manual position.
Figure 13. Manual-Off-On SW. (Man. Position)
2.  The AC power indicator lamp (Figure 14) should be lit 
(
on).
Figure 14. AC Power Indicator Lamp (ON)
3.  Wait a few seconds and water should begin to flow 
from the discharge hose.
4.  If water is not flowing from the discharge hose or not 
flowing freely after a few minutes, remove the power 
from the pump and check the system for leaks.
5.  To stop the pump from pumping, place the operation 
switch in the 
oFF position.
ON
automatic operation
1.  For  unattended  operation  of  the  pump,  place  the 
operation switch (Figure 15) in the 
auto position.
Figure 15. Manual-Off-On SW. (AUTO Position)
2.  In the 
auto mode the pump will run as long as there 
is a sufficient amount of water for the 
start float switch 
to be activated. This water level is determined by the 
setting of the float switches.
The 
stop  float switch  contacts will open when the 
water level is low and power will be removed from the 
pump's motor.
3.  Once the water level has risen back to the appropriate 
level the 
start float switch contacts will close and power 
will be restored to the pump's motor.
Shut-down
1.  Place the 3-position operation switch on the control 
box in the 
oFF position (Figure 16).
Figure 16. Manual-Off-On SW. (OFF Position)
2.  Verify that the control box power ON light is 
oFF.
3.  Remove the power from the pump by turning off the 
circuit  breaker or switch that provides  power to the 
pump. Remember to make sure that hands are dry (not 
wet), and feet are not standing in water when removing 
or disconnecting power from the pump.
4.  Using the lifting rope, lift the pump up from its current 
position.  Remove  the  discharge  hose  from  the 
discharge port on the pump.
5.  Remove  all  power  cables  and  float  switches  from 
the control box. Place cables and float switches in a 
suitable container where they will not get damaged.