DIGItAL cOntROL PAnEL cOMPOnEntS
Figure 7 displays the components associated with the 
digital control panel. A brief description of each component 
is described below
1. 
Emergency Stop Button — Press emergency stop 
button to stop pump in an emergency. Turn knob 
counterclockwise to disengage the stop button.
2. 
ignition Switch — Insert the ignition key here to start 
the engine. Turn the key clockwise to the 
ON position, 
then continue turning clockwise to the 
START position 
and release. To stop the engine turn the key fully 
counterclockwise to the 
STOP position.
3. 
Pumping  Control Switch — This 3-position switch 
controls the pumping of the pump. The rightmost 
position (
REMOTE) is for use with the remote control 
unit, the leftmost position (
LOCAL) is for normal 
pumping operation, and the centermost position 
(
CENTER OFF) prevents pumping.
4. 
Remote Cable Receptacle — Insert the remote 
control cable into this receptacle.
5. 
Manual Cylinder Jogging Switch — This  2-position 
switch allows the operator to manually jog the cylinders 
to assist in clearing material line packs and is used to 
test pumping pressure (See Initial Start-up Procedure 
section of this manual for testing procedure).
The 
leftmost position jogs cylinder “A” and the 
rightmost position jogs cylinder “B”.
6. 
Cylinder Stroke Control Switch — This 2-position 
switch controls the pumping function. The leftmost 
position (
aUTOMaTiC) sets the pump to automatic 
cycling. Set the switch to this position for normal pump 
operation.
The rightmost position (
JOG) changes the pump from 
automatic to manual cycling. This allows the cylinders 
to be manually cycled using the 
manual cylinder 
jogging switch.
7. 
vibrator  Cable Receptacle (Option)  — Insert the 
vibrator cable into this receptacle.
8. 
Direction Control Switch —This 2-position switch 
controls the direction of flow for any mix in the pump.  
The leftmost position sets the pumping direction to 
forward and the rightmost position sets the pumping 
direction to reverse.
9. 
Stroke volume  Control  Switch  — Increases or 
decreases the number of strokes per minute of the 
pump.
10. 
Scroll Switch — Allows the operator to scroll the 
various readout screens.
11. 
Reset Switch — Allows the operator to reset the 
stroke counter.
12. 
Digital Readout Screen — Displays and monitors the 
various functions of the machine.
13. 
Accumulator Pressure Gauge — This gauge 
monitors the internal pressure of the Accumulator tank. 
Normal internal pressure should read approximately 
1750 PSI during pumping.
14. 
Main Pressure Gauge — This gauge monitors 
the system pressure while pumping material. The 
maximum pressure rating is 4400 ~ 4400 PSI.
Figure 7. Pump Digital Control Panel Components
ACCUMULATOR
PRESSURE
PUMPING
PRESSURE
1
2
10
11
4
5
6
8
12
3
13
9
14
OFF
ON
IGNITION
REMOTE
CONTROL
FLOW
DIRECTION
VOLUME
LOCAL
FORWARD
AUTOMATIC
JOG
RESET
SET
DECREASE
INCREASE
SCROLL
JOG “A”
CYLINDER STROKE
JOG “B”
REVERSE
CENTER
OFF
REMOTE
START
0
1000
2000
3000
5000
4000
0
500
1000
2000
3000
2500
1500
E
m
erg
ency S
top
VIBRATOR
RECEPTACLE
7