Troubleshooting
3A0245B
19
Electrical Problems
Symptom: Unit does not run or stops running.
Perform Pressure Relief Procedure; page 6.
Plug unit into correct voltage, grounded outlet
Set power switch OFF for 45 seconds and then ON 
again (this ensures drywall feed pump is in default 
flow control mode).
Turn flow control knob clockwise 1/2 turn
Trigger learned controller
View digital display
If no digital display is available, use the con-
trol board status light to troubleshoot prob-
lems. turn ON/OFF switch to OFF, remove 
control cover and then turn power back ON. 
Observe status light. Blinking LED total 
count equals digital error code (example: two 
blinks equals E=02).
To avoid electrical shock or moving parts hazards when 
covers are removed for troubleshooting, wait 45 sec-
onds after unplugging power cord for stored electricity 
to dissipate. Keep clear of electrical and moving parts 
during troubleshooting procedures.
TYPE OF PROBLEM
WHAT TO CHECK
HOW TO CHECK
Drywall feed pump does not 
run at all
See flow chart, page 25.
Digital display is blank
Control board status light 
never lights
Drywall feed pump does not 
run at all
Check transducer or transducer 
connections.
1.
Make sure there is no pressure in the system (see 
Pressure Relief Procedure, page 6). Check fluid 
path for clogs.
2.
Make sure a minimum of 50 ft of hose is connected 
to the unit.
3.
Set drywall feed pump to OFF and disconnect power 
to drywall feed pump. 
4.
Check transducer and connections to control board.
5.
Disconnect transducer from control board socket. 
Check that transducer and control board contacts 
are clean and secure.
6.
Reconnect transducer to control board socket. 
Connect power, turn unit ON, set pump to PRIME 
position, and turn control knob 1/2 turn clockwise. If 
drywall feed pump does not run properly, turn unit 
OFF and go to next step.
7.
Install new transducer. Connect power, turn unit ON, 
set pump to PRIME position, and turn control knob 
1/2 turn clockwise. Replace control board if drywall 
feed pump does not run properly.
Digital display shows E=02
Control board status light 
blinks 2 times repeatedly