Hitachi FD2 1590 Manuel D’Utilisation

Page de 50
Operation
311879F
11
Operation
Pressure Relief Procedure
1.
Shut off the air to the pump.
2.
Open the dispensing valve, if used.
3.
Open the fluid drain valve to relieve fluid pressure, 
having a container ready to catch the drainage.
Sanitize the Pump Before First Use
It is the user’s responsibility to properly sanitize the 
pump before first use. It is up to the user whether this 
will include disassembling and cleaning individual parts 
or simply flushing pump with a sanitizing solution. As 
necessary, follow the steps under Starting and Adjust-
ing the Pump 
below, under the Service section on 
page 16, or under Flushing on page 13. 
Starting and Adjusting the Pump
1.
Be sure the pump is properly grounded. Refer to 
Grounding on page 4.
2.
Check connections to be sure they are tight. Tighten 
fluid inlet and outlet connections securely.
3.
Place the suction tube (if used) in fluid to be 
pumped.
4.
Place the end of fluid hose (L) into an appropriate 
container. 
5.
Close the fluid drain valve (J).
6.
Back out the air regulator (C) knob, and open all 
bleed-type master air valves (B, E).
7.
If the fluid hose has a dispensing device, hold it 
open while continuing with the following step. 
8.
Slowly increase air pressure with the air regulator 
(C) until the pump starts to cycle. Allow the pump to 
cycle slowly until all air is pushed out of the lines 
and the pump is primed.
Pump Shutdown
At the end of the work shift, relieve pressure.
Read the PRESSURIZED EQUIPMENT HAZARD 
warnings on page 4.
The equipment stays pressurized until pressure is man-
ually relieved. To reduce the risk of serious injury from 
pressurized fluid or splashing fluid, follow this proce-
dure whenever you:
are instructed to relieve pressure
stop pumping
check, clean or service any system equipment
Read the TOXIC FLUID OR FUMES HAZARD warn-
ings on page 5. Never move or lift a pump under pres-
sure. If dropped, the fluid section may rupture. Always 
follow the Pressure Relief Procedure before lifting the 
pump.
 If fluid inlet pressure to the pump is more than 
25% of outlet working pressure, the ball check 
valves will not close fast enough, resulting in inef-
ficient pump operation.