Hitachi FD2 1590 Manuel D’Utilisation
Troubleshooting
14
311879F
Troubleshooting
•
Relieve the pressure before checking or servicing
the equipment.
the equipment.
•
Check all possible problems and causes before dis-
assembling the pump.
assembling the pump.
To reduce the risk of serious injury, whenever you are
instructed to relieve pressure, always follow the Pres-
sure Relief Procedure on page 11.
instructed to relieve pressure, always follow the Pres-
sure Relief Procedure on page 11.
PROBLEM
CAUSE
SOLUTION
Pump cycles at stall or fails to hold
pressure at stall.
pressure at stall.
Worn check valve balls (301), seats
(201) or o-rings (202).
(201) or o-rings (202).
Replace. See 18.
Pump will not cycle, or cycles once
and stops.
and stops.
Air valve is stuck or dirty.
Disassemble and clean air valve. See
page 16. Use filtered air.
page 16. Use filtered air.
Check valve ball (301) severely
worn and wedged in seat (201) or
manifold (102 or 103).
worn and wedged in seat (201) or
manifold (102 or 103).
Replace ball and seat. See page 18.
Check valve ball (301) is wedged
into seat (201), due to overpressur-
ization.
into seat (201), due to overpressur-
ization.
Install Pressure Relief Valve
(see page 10).
(see page 10).
Dispensing valve clogged.
Relieve pressure and clear valve.
Pump operates erratically.
Clogged suction line.
Inspect; clear.
Sticky or leaking balls (301).
Clean or replace. See page 18.
Diaphragm ruptured.
Restricted exhaust.
Remove restriction.
Air bubbles in fluid.
Suction line is loose.
Tighten.
Diaphragm ruptured.
Loose inlet manifold (102), dam-
aged seal between manifold and
seat (201), damaged o-rings (202).
aged seal between manifold and
seat (201), damaged o-rings (202).
Loose diaphragm shaft bolt (107).
Damaged o-ring (108).
Chattering - noisy operation.
Check valve balls do not seat prop-
erly/cleanly due to imbalance
between fluid inlet and outlet line
sizing. Noise is accentuated with
light viscosity fluids.
erly/cleanly due to imbalance
between fluid inlet and outlet line
sizing. Noise is accentuated with
light viscosity fluids.
Reduce size/diameter of inlet line rela-
tive to outline line. Outlet line size
should not exceed pump size.
tive to outline line. Outlet line size
should not exceed pump size.