Performance Chart - 2150
311879F
49
Performance Chart - 2150
Test Conditions: Pump tested in water with inlet submerged
Fluid Pressure Curves
at 120 psi (0.7 MPa, 7 bar) operating air pressure
at 100 psi (0.7 MPa, 7 bar) operating air pressure  
at 70 psi (0.48 MPa, 4.8 bar) operating air pressure  
at 40 psi (0.28 MPa, 2.8 bar) operating air pressure 
To find Fluid Outlet Pressure
(psi/MPa/bar) at a specific fluid flow (gpm/lpm) and 
operating air pressure (psi/MPa/bar):
1. Locate fluid flow rate along bottom of chart.
2. Follow vertical line up to intersection with selected 
operating air pressure curve.
3. Follow left to scale to read fluid outlet pressure.
Air Consumption Curves
at 120 psi (0.7 MPa, 7 bar) operating air pressure
at 100 psi (0.7 MPa, 7 bar) operating air pressure  
at 70 psi (0.48 MPa, 4.8 bar) operating air pressure  
at 40 psi (0.28 MPa, 2.8 bar) operating air pressure 
To find Pump Air Consumption
(scfm or m
3
/min) at a specific fluid flow (gpm/lpm) and 
operating air pressure (psi/MPa/bar):
1. Locate fluid flow rate along bottom of chart.
2. Read vertical line up to intersection with selected 
operating air pressure curve.
3. Follow left to scale to read air consumption.
Fl
ui
d O
u
tl
et 
Pr
ess
ure
 
psi
 (MP
a, 
ba
r)
20
40
60
80
100
120
0
(0.84, 8.4)
(0.7, 7)
(0.55, 5.5)
(0.41, 4.1)
(0.28, 2.8)
(0.14, 1.4)
20
40
60
80
100
120
0
(0.84, 8.4)
(0.7, 7)
(0.55, 5.5)
(0.41, 4.1)
(0.28, 2.8)
(0.14, 1.4)
140
(0.96, 9.6)
160
(1.10, 11.0)
180
(1.24, 12.4)
Air
 Co
n
s
um
pti
o
n
Fluid Flow
gpm (lpm)
scfm
 (
m
3
/m
in)
Fluid Flow
gpm (lpm)
20
(75)
40
(151)
60
(227)
80
(302)
100
(378)
120
(454)
140
(530)
160
(605)
20
(75)
40
(151)
60
(227)
80
(302)
100
(378)
120
(454)
140
(530)
160
(605)
180
(681)
TI8740A
TI8742A
TI8742A
TI8741A