Pump Accessories
Follower Plate (A): ensures a good prime. Place 
follower plate on grease and rotate while pressing firmly 
to level material. Order part number 247700 for 60# and 
90# automatic lube pump modules; 247701 for 120# 
refinery reservoir; or 247702 for 400# refinery reservoir.
Pump Outlet Drain Valve (D): helps relieve fluid 
pressure in pump when pump is shut off. Install valve 
close to pump fluid outlet. Order valve, Part No. 111229.
Hydraulic Power Supply
The hydraulic power supply system (U) must have a 
pressure reducing valve and a pressure-compensated 
flow control. A flow control valve (Q) is required to limit 
the incoming flow to the reciprocator to a maximum of 3 
gpm (11 lpm)
.
Hydraulic Lines
Shut-off Valves (H, L): installed on the hydraulic supply 
and return lines. Order Part No. 108537 and 112578.
Drain Line: Monitor the weepage of hydraulic fluid or 
lubricant. If it seems excessive or increases suddenly, 
the reciprocator/pump seals may need to be changed. 
See F
F
IG
. 2
Hoses: Use a minimum 1/2 inch supply line (R) and 
minimum 3/4 inch return line (F) on the reciprocator. 
Contact your Graco representative for details of line 
sizing.
Pressure Reducing Valve (N): circulates excess 
hydraulic fluid pressure back to the hydraulic power 
supply. Install this valve (N) in the hydraulic supply line 
with a drain hose (W) teed into the hydraulic return line 
(F). Limit supply pressure to a maximum 600 psi (4.1 
MPa, 41 bar).
Accumulator (P): reduces hammering effect caused by 
the motor when it reverses direction.
Fluid-filled Pressure Gauge (M), Part No. 112567: 
monitors hydraulic pressure to the reciprocator during 
startup. See F
. 1. Use the gauge for initial adjustment 
of the reciprocator. It can be removed after adjustment.
Pump Outlet Drain Valve
A pump outlet drain (D) is required in your system. 
This valve helps relieve pressure in the displace-
ment pump and hose when shutting down system 
and in case of a clogged outlet hose. Install valve 
close to pump outlet.
Mount pump securely so it cannot move around 
during operation. Failure to do so could result in 
personal injury and/or equipment damage.
Limit Fluid Flow to Reciprocator
To reduce the risk of overpressurizing the hydraulic 
reciprocator which could cause a rupture and serious 
injury, including fluid injection, a hydraulic system 
must have a means to limit the incoming fluid flow to 
the reciprocator to a maximum of 3 gpm (11 lpm) and 
600 psi (4.1 MPa, 41 bar). See description below.
Pressure gauge (M), pressure reducing valve (N) 
and a flow control valve (Q) are included in the 
Hydraulic Fluid Control Kit 247538 or 247705, 
which can be ordered separately.