SECTION 1.0 - INTRODUCTION
The purpose of this manual is to assist the user in developing 
safe and efficient procedures for the installation, maintenance
and operation of the equipment. For additional information, 
refer to NEMA Standards Publication PB2.1 “General Instructions 
for Proper Handling, Installation, Operation, and Maintenance 
of Deadfront Distribution Switchboards rated 600 volts or less”
which is available from the NEMA web site (www.nema.org).
Contact the nearest Siemens representative if any additional
information is required.
Siemens warrants that on the date of shipment all goods 
manufactured by Siemens are free of non-conformities in 
workmanship and materials. If within one year from date 
of initial operation, but not more than eighteen months from 
date of shipment by Siemens, of any item of the goods, pur-
chaser discovers that such item was not as warranted above, 
and promptly notifies company in writing thereof, company 
shall remedy such defect by, at company’s option, adjustment,
repair or replacement of the item and any affected part of the
goods. Refer to “Standard Terms and Conditions of Sale” for 
complete warranty terms.
1.1 Qualified Person
For the purpose of this manual a Qualified Person is one who 
is familiar with the installation, construction or operation of the
equipment and the hazards involved. In addition, this person 
has the following qualifications:
1.1.1. Training and authorization to energize, de-energize, clear, 
ground and tag circuits and equipment in accordance with 
established safety practices.
1.1.2. Training in the proper care and use of protective equip-
ment such as rubber gloves, hard hat, safety glasses, 
face shields, flash clothing, etc., in accordance with 
established safety procedures.
1.1.3. Training in rendering first aid.
1.1.4. Knowledgeable of NEC requirements and other 
applicable codes, laws and standards
1.2 Signal Words
The signal words “Danger,” “Warning” and “Caution” 
used in this manual indicate the degree of hazard that may 
be encountered by the user. These words are defined as:
1.2.1. Danger - Indicates an imminently hazardous situation 
which, if not avoided, will result in death or serious injury.
1.2.2. Warning - Indicates a potentially hazardous situation which, 
if not avoided, could result in death or serious injury.
1.2.3. Caution - Indicates a potentially hazardous situation which, 
if not avoided may result in minor or moderate injury.
1.3 Dangerous Procedures
In addition to other procedures described in this manual as dan-
gerous, user personnel must adhere to the following warnings:
1.3.1. Danger! High Voltage. Qualified personnel only. Lock 
off all power to this equipment before working inside. 
Always work on de-energized equipment. Always 
de-energize equipment before performing any tests, 
maintenance or repair.
1.3.2. Warning! Always perform maintenance on the inter-
rupting device after the closing mechanism(s) are 
discharged.
1.3.3. Caution! Always let an interlock device or safety mech-
anism perform its function without forcing or defeating 
the device.
1.3.4. Caution! Hydrocarbon spray propellants and hydro-
carbon compounds will cause degradation of certain 
plastics. Contact your local Siemens representative 
before using these products to clean or lubricate 
components during installation or maintenance.
1.4 Field Service 
“Siemens Industrial Services” can provide the following support
services for switchboards. Call 1-800-241-4453 to obtain addi-
tional information and schedule an appointment.
• Start-up Commissioning
• Component and System Testing
• Maintenance (Scheduled and Preventative)
• Repair and Refurbishing
• On Site Operational Training
1.5 General Description
Siemens switchboards are designed and manufactured to 
perform efficiently under normal operating conditions. The
instructions included in this manual are provided to aid in 
obtaining long and economical service from your switchboards. 
For proper operation and maintenance, this information should
be distributed to the owner’s operators and engineers.
These instructions cover the standard construction details 
of Siemens’ switchboards including auxiliary equipment and 
necessary accessories. Any special equipment furnished in 
accordance with purchase order requirements are covered 
by supplementary instruction books.
The switchboards described in this manual are the dead- 
front type as defined in NFPA70 (NEC), UL891 and NEMA 
PB2. All parts, conductors, and insulation materials are 
designed and constructed to suit the voltage class of 
the equipment and are enclosed within grounded metal 
enclosures.
The equipment furnished has been designed to operate in a 
system having the circuit capacity specified by the purchaser. 
If, for any reason, the equipment is later used in a different 
system, or if the short-circuit capacity of the system is 
increased, the momentary rating of the switchboards, the 
interrupting capacity of the protective devices and the bus 
capacity must be checked. Should the service be changed, 
the equipment must be checked to assure that the short 
circuit capacity, amperage and voltage class of the equip-
ment meets or exceeds the requirement of the new system.
Switchboards are free-standing units rated 6000 amperes or 
less at 600 volts AC or less. A typical switchboard will contain 
the service entrance section with main devices and distribution
sections with branch devices. The sections contain disconnect
devices, protective devices, auxiliary equipment, and any current 
Introduction
2