•  NEWTAPE=YES|NO 
 
This is an optional parameter used to cause a new tape volume in the 
Archive Manager database to be opened at the start of migration 
processing.   If omitted, the default value of “NO” is used. 
•  DB2SSID=xxxx  
 
This mandatory parameter is used to specify the subsystem identifier of 
the DB2 subsystem to be used during execution of the utility.   The 
subsystem identifier ‘xxxx’ can be 1-4 characters in length. 
•  PLAN=xxxxxxxx 
 
This is an optional parameter which is used to specify the DB2 plan name 
to be used during execution of the utility, where ‘xxxxxxxx’ is the 1-8 
character identifier of the plan.  If omitted, a default value of OTDBL100 is 
used.  Refer to “Perform DB2 system modifications” page 25 for 
information about DB2 Manager plan creation processing. 
•  S100PRI=nnnnnnn  
 
This is an optional parameter specifying the number of primary extent 
blocks to be used during allocation of temporary dataset OTDBS100 used 
during execution of the utility.   ‘nnnnnnn’ is a 1-7 digit numeric value in 
the range 1-8388607.  If omitted, a default value of 10000 will be used.  
The length of each block will be equal to 100 times the concatenated field 
lengths of the table columns which are used to uniquely index each row in 
the table (see “SQLIN entry specification”  on page 85 for a discussion of 
the unique index requirement). 
• 
S100SEC=nnnnnnn  
 
This is an optional parameter specifying the number of secondary extent 
blocks to be used during allocation of temporary dataset OTDBS100 used 
during execution of the utility.  ‘nnnnnnn’ is a 1-7 digit numeric value in 
the range 1-8388607.  If omitted, a default value of 10000 will be used.  
The length of each block will be equal to 100 times the concatenated field 
lengths of the table columns which are used to uniquely index each row in 
the table (see “SQLIN entry specification”  on page 85 for a discussion of 
the unique index requirement).
  
• 
S100UNIT=xxxxxxxx  
 
This is an optional parameter specifying the unit name to be used for 
allocation of temporary dataset OTDBS100 used during execution of the 
utility.  ‘xxxxxxxx’ is any valid disk or VIO unit name.  If omitted, a default 
value of ‘VIO’ is used.  
  
• 
ROWMAX=nnnnnn|0 
 
 
This is an optional parameter specifying the maximum number of rows to 
be migrated from DB2 by the utility.   The utility will terminate processing