Troubleshooting
With proper installation, operation, and maintenance your appliance will provide years of 
trouble-free service. If you do experience a problem, this troubleshooting guide will assist 
a qualified service person in the diagnosis of a problem and the corrective action to be 
taken. This troubleshooting guide can only be used by a qualified service technician.
Error Message
Possible Cause
Corrective Action
Bad wall control or control board
3 wires have loose connections or installed 
wrong
Replace wall control or control board
Check connections
LOW BATTERY
Battery supply on battery backup is drained
Recharge battery
BAD TC DROP TUBE
TC = Thermocouple
Drop tube thermocouple is broken or leads are 
reversed
Check connections
Replace thermocouple
BAD TC FIREPOT
TC = Thermocouple
Firepot thermocouple is broken or leads are 
reversed
Check connections
Replace thermocouple
SNAP DISC TRIPPED
Overheat sensor (snap disc) has tripped 
Unplug the appliance and then manually 
reset snap disc
VACUUM SW ERROR
SW = Switch
Vacuum switch is bad
Vacuum hose is plugged/disconnected
Check connections.  By-pass vacuum 
with jumper wire, if run, switch is bad.  
Replace switch
Check vacuum hose 
COMB BLOWER JAMMED
Combustion blower is blocked/jammed
Remove blockage
Replace blower if necessary
Must unplug the appliance to clear error
AUGER JAMMED
Auger jammed, feed motor bad
Pull the feed system and inspect
Clear jam and then press Retry Button
MISSED IGNITION
Igniter bad or poor harness connection 
Out of fuel or fuel is bridging in hopper
Faulty firepot thermocouple, connection is 
shorted
Check connections, if OK replace igniter
Break up bridging pellets
Refill hopper 
Replace the thermocouple and then 
press Retry
MIN FIREPOT TEMP
Out of fuel
Refill hopper
Add handful of pellets to the firepot
Press the Retry button
MAX DROP TUBE TEMP
Wrong fuel table setting  
Flame height set too high
Confirm setting matches burning fuel
Adjust flame height
CONV BLOWER JAMMED
Convection blower blocked/jammed
Remove blockage
Replace blower if necessary
Must unplug appliance to clear error
CHECK ASHPAN
Auto-clean jammed
Auto-clean switch is bad
Linkage has become disconnected
If ash pan is empty, check for a jam. Use 
a screw driver and firmly push in the 
firepot floor holes and flex spring and 
push toward home to release jam.
Replace switch
Reconnect linkage.
Hopper lid open while you refill hopper
Switch is out of adjustment (auger will not 
function)
Fill hopper between cycles
Adjust or replace switch
SCREEN GOES BLANK
Static discharge or nearby lightening or
Electric Fast Transients at the input mains
Unplug the power to the appliance and 
plug it back in