Mt. Vernon Pellet Insert (AE)
Ash Build Up in Firebox
Pellets Back Up
In Feed Tube
Firepot Overfills
Figure 36.1
If the ash build-up exceeds the half way point in the firepot 
before it automatically cleans, then the firepot is not being 
cleaned often enough.  
Another symptom is if clinkers are adhering to the sides 
of the firepot. Double check the wall control to ensure the 
proper setting has been selected for the fuel you are burning.  
If that is correct, change the setting to “Utility Pellet”.
D. High Ash Fuel Content Maintenance
Frequency:  As needed
By:  Homeowner
WARNING
Fire and Smoke Risk.
High ash fuels or lack of maintenance 
can cause firepot to overfill. Follow 
proper shutdown procedure if ash buildup 
exceeds half way point in firepot.
Failure to do so could result in smoking, 
sooting and possible hopper fires.
E.  Baffle Removal
Baffle
Latches
Insert flat head screw driver into “V”
section and push down and the bottom
of the latch will fall forward off of post
Locating ears - 1 on
each side.  Fit behind
bottom edge.
Figure 36.2
WARNING
Cast iron is a very heavy material. The baffle is 
made of cast iron and therefore is heavy and awk-
ward at times to maneuver.  Clear and prepare 
your work area before you begin.  
a.  The appliance must be in complete shutdown, com-
pletely cool and the exhaust blower off.
b. Open door.
c.  The baffle is located at the top inside of firebox.
d.   Remove baffle by placing a flat head screw driver into 
the slot of the latches located in the upper corners and 
push down.  The bottom of the latch will fall forward off 
of the post.  Lift the baffle up and then out toward you.  
Figure 36.2.
e.  To replace the baffle, place the 2 locating ears behind 
the bottom edge and tilt the baffle up and into place
f.  The baffle must be centered in the firebox before latch-
ing it in place.  If it is not centered the latch is trapped 
between the baffle and side of the firebox instead of 
latching properly.  
g.  The bottom of the latches will fit over the posts.  Push 
the top of the latch forward to lock latch into place.