Troubleshooting tips.
No display
Check for 24 VAC at thermostat; display 
is blank when 24 VAC is not present.
System fan does not
Verify that wiring is correct.
come on properly
All thermostat buttons
Verify that 24 VAC is present; unit 
are inoperative
locks out when 24 VAC is not present.
Thermostat turns on and
Adjust temperature differential (see 
off too frequently
Setting a New Temperature Differential).
Program schedule activates Check time (AM/PM) set on 
at the wrong time
thermostat (see Programming).
Thermostat does not 
Verify that it is in Program mode; PROG
follow program
displays solid; check time (AM/PM); 
check if in Hold mode (PROG flashing).
“PROG” flashes
Press Hold button to remove from 
(in Hold mode)
Hold mode.
Fan runs continuously
Check Fan Auto/On switch. If set to 
ON position, fan will run continuously.
Room temperature is 
Verify that wall hole is plugged 
not correct
with putty or insulation.
Compressor doesn’t run
There is a 3 minute time delay and a 
or turn off immediately 
3 minute minimum run time for the 
when changing function
compressor when it turns on/off.
or setting
Fan doesn’t run or turn off
This is normal. On some models, the 
immediately when changing  fan may have a 3 minute minimum 
function or setting
run time/off time delay.
“LO bat” displays on screen
Replace batteries with 2 fresh “AA”
alkaline batteries.
Display reads “12:00 PM”
Set clock/time.
Problem not listed above
Press the Reset button once. Reset 
button function: time, day and mode 
changed to last saved settings (saved 
after power loss or when exiting 
program setup; configuration and 
program settings are unchanged).
Problem
Solution