Quad II Classic Manuel D’Utilisation

Page de 4
Service & Information
Authorised QUAD Service Centres in the U.K. and North America
www.quad-hifi.co.uk
If  your QUAD equipment requires servicing (including valve replacement) you should return 
it to the dealer from whom the equipment was purchased. 
If  you are abroad and there is no suitable dealer in your area, please contact the distributor 
for the country in which it was purchased or QUAD Electroacoustics Ltd. 
It is user's responsibility, whether the equipment is under warranty or otherwise, to ensure 
that equipment for service is returned carriage paid and in the original packaging. You 
should enclose a brief  note with your name and address and the reason for returning the 
equipment. 
For information on authorised service centres worldwide contact QUAD Electroacoustics Ltd. A worldwide distributor 
list is available on the QUAD website: 
SPECIFICATIONS
Quad II Classic Monobloc valve power amplifier
Input sensitivity
1.4V RMS
Power output
15W RMS
Output Impedance
8 Ohms
THD @ 700 Hz
0.3% @ 12w
Residual hum and noise
Better than -90 dB
Frequency response
10 Hz - 20 kHz (± 0.2 dB)
Damping factor
11.75 @ 700 Hz (referred to 8 Ohms)
Power consumption
90VA maximum
Valves
2 x EF86, 2 x KT66, 1 x GZ34
Dimensions (mm)
335 x 121 x 171
Weight
8.3 Kg
for long periods of time, unplug it from the wall outlet and disconnect the antenna or cable system. This will prevent 
damage to the product due to lightning and power-line surges.
Antenna Grounding: If an outside antenna or cable system is connected to the product, be sure the antenna or cable 
system is grounded so as to provide some protection against voltage surges and built-up static charges. Article 810 of 
the National Electrical Code, ANSI/NFPA 70, provides information with regard to proper grounding of the mast and 
supporting structure, grounding of the lead-in wire to an antenna discharge unit, size of grounding conductors, location 
of antenna-discharge unit, connection to grounding electrodes, and requirements for the grounding electrode. (Refer to  
diagram)
Power Lines:  An outside antenna system should not be located in the vicinity of overhead power lines or other 
electric light or power circuits, or where it can fall into such power lines or circuits. When installing an outside 
Read Instructions: All the safety and operating instructions should be read before the product is operated.
antenna system, extreme care should be taken to keep from touching such power lines or circuits as contact with 
them might be fatal.
Retain Instructions: The safety and operating instructions should be retained for future reference.
Overloading: Do not overload wall outlets, extension cords, or integral convenience receptacles as this can result 
Heed Warnings: All warnings on the product and in the operating instructions should be adhered to.
in a risk of fire or electric shock.
Follow Instructions: All operating and use instructions should be followed.
Object and Liquid Entry: Never push objects of any kind into this product through openings as they may touch 
Cleaning: Unplug this product from the wall outlet before cleaning. Do not use liquid cleaners or aerosol cleaners. 
dangerous voltage points or short-out parts that could result in a fire or electric shock.  
Use a damp cloth for cleaning.
Heat: The product should be situated away from heat sources such as radiators, heat registers, stoves, or other 
Attachments: Do not use attachments not recommended by the product manufacturer as they may cause hazards.
products (including amplifiers) that produce heat.
Water and Moisture: Do not use this product near water - for example, near a bath tub, wash bowl, kitchen sink, 
Servicing: Do not attempt to service this product yourself as opening or removing covers may expose you to 
or laundry tub, in a wet basement; or near a swimming pool; and the like.
dangerous voltage or other hazards.  Refer all servicing to qualified service personnel.
Accessories: Do not place this product on an unstable cart, stand, tripod, bracket, or table. The product may fall, 
Damage Requiring Service: Unplug this product from the wall outlet and refer servicing to qualified service 
causing serious injury to a child or adult, and serious damage to the product. Use only with a cart, stand, tripod, bracket 
personnel under the following conditions:
or table recommended by the manufacturer, or sold with the product. Any mounting of the product should follow the 
a)   When the power supply-cord or plug is damaged
manufacturer's instructions, and should use a mounting accessory recommended by the manufacturer.
b)   If liquid has been spilled, or objects have fallen into the product
Moving the Product: A product and cart combination should be moved with care. Quick stops, excessive force, and 
c)   If the product has been exposed to rain or water.
uneven surfaces may cause the product and cart to overturn.
d)   If the product does not operate normally by following the operating instructions.  Adjust only those controls that are 
Ventilation: Slots and openings in the cabinet are provided for ventilation and to ensure reliable operation of the 
covered by the operating instructions as an improper adjustment of other controls may result in damage and will often 
product and to protect it from overheating, and these openings must not be blocked or covered. The openings 
require extensive work by a qualified technician to restore the product to its normal operation.
should never be blocked by placing the product on a bed, sofa, rug, or other similar surface. This product should not 
e)   If the product has been dropped or damaged in any way.
be placed in a  built-in installation such  as  a  bookcase or rack  unless  proper ventilation is  provided or the 
manufacturer's instructions have been adhered to.
f)    When the product exhibits a distinct change in performance - this indicates a need for service.
Power Supply Cords: Power supply cords should be routed so that they are not likely to be walked on or pinched by 
Replacement Parts: When replacement parts are required, be sure the service technician has used replacement 
items placed upon or against them, paying particular attention to cords at plugs, convenience receptacles, and the 
parts  specified  by  the  manufacturer  or  have  the  same  characteristics  as  the  original  part.    Unauthorised 
substitutions may result in fire, electric shock, or other hazards.
point where they exit from the product.
Safety Check: Upon completion of any service or repairs to this product, ask the service technician to perform 
Power Sources: This product should be operated only from the type of power source indicated on the marking 
safety checks to determine that the product is in proper operating condition.
label. If you are not sure of the type of power supply to your home, consult your product dealer or local power 
company. For products intended to operate from battery power, or other sources, refer to the operating instructions.
Polarisation: This product is equipped with a polarized alternating-current line plug (a plug having one blade 
wider than the other). This plug will fit into the power outlet only one way. This is a safety feature. If you are unable 
to insert the plug fully into the outlet, try reversing the plug. If the plug should still fail to fit, contact your electrician 
to replace your obsolete outlet. Do not defeat the safety purpose of the polarized plug.
Lightning: For added protection for this product during a lightning storm, or when it is left unattended and unused 
Warning: To resist the risk of fire or electrical shock, do not expose this product to rain or moisture. The product 
must not be exposed to dripping and splashing and no object filled with liquids - such as a vase of flowers - should 
be placed on the product. 
No naked flame sources - such as candles - must be placed on the product.
Service: Equipment for sevicing should be returned to the suplying dealer, or to the appointed service agents for 
your area. The addresses of Service Agents for the UK , USA and Canada are listed on the rear cover of this manual.
Important Safety Precautions - Please Read Carefully!
IMPORTANT NOTICE TO UK USERS
The appliance cord is terminated with a UK approved mains plug fitted with a 5A fuse. If 
the fuse needs to be 
replaced, an ASTA or BSI approved BS1362 fuse rated at 5A must be used. If you need to change the mains plug, 
remove the fuse and dispose of this plug safely immediately after cutting it from the cord.
Connecting a Mains Plug 
The wires in the  mains lead are coloured in accordance with the code:  
Blue: NEUTRAL    Brown: LIVE    Green & Yellow: EARTH. 
As  these  colours  may  not  correspond  to  the  coloured 
markings identifying the terminals in your plug, proceed as 
follows: 
The wire coloured BLUE must be connected to the terminal 
marked with the letter N or coloured BLUE or BLACK. The wire 
coloured BROWN must be connected to the terminal marked 
with  the  letter  L  or  coloured  BROWN  or  RED.  The  wire 
coloured  GREEN  &  YELLOW  must  be  connected  to  the 
terminal  marked  with  the  letter  E  or  coloured  GREEN  or 
GREEN & YELLOW or marked with the Earth Symbol
GREEN 
&
YELLOW
(EARTH)
BLUE
(NEUTRAL)
(LIVE)
BROWN
FUSE
(5 A)
WARNING
The mains power switch for this appliance is located on the rear panel. To permit free access to this switch the 
apparatus must be located in an open area without any obstructions.
CAUTION 
Use of controls or adjustments, or the performance of procedures other than those specified may result in hazardous
 radiation exposure.
IMPORTANT NOTICE
The IEC socket which fits into the mains connector located on the  rear panel of this unit is a moulded unit. 
If this  unit becomes damaged in any way do not attempt to repair or connect a replacement plug to the cord.
Consult your dealer to purchase a suitable replacement.
WARNING
This equipment uses valves (tubes) which get hot. Do not touch the glass envelopes of the valves while the 
equipment is in use or within 30 minutes after the equipment has been switched off.
USA
IAG America, Inc.
15 Walpole Park South 
Walpole 
MA 02081 
Tel: +1 508 850 3950
U.K. 
QUAD Electroacoustics Ltd.
IAG House, Sovereign Court, 
Ermine Business Park, 
Huntingdon, 
Cambs PE29 6XU, 
England.
Tel:+44 (0)1480 447700 
Fax:+44 (0)1480 431767
CANADA
Korbon Trading Ltd
6800 Kitimat Road
Units 19-20
Mississauga
Ontario
Tel: +1 905 567 1920
The  lightning  flash  with  arrowhead  symbol,  within  an  equilateral  triangle,  is 
intended to alert the user to the presence of uninsulated dangerous voltage within 
the product’s enclosure that may be of sufficient magnitude to constitute a risk of 
electric shock to persons.   
The exclamation point within an equilateral  triangle is intended to alert the user to 
the presence of important operating and maintenance (servicing) instructions in 
the literature accompanying the appliance.
TO REDUCE THE RISK OF ELECTRIC SHOCK
DO NOT REMOVE COVER (OR BACK)
NO USER-REMOVEABLE PARTS INSIDE
REFER SERVICING TO QUALIFIED PERSONNEL
CAUTION!
RISK OF ELECTRIC SHOCK
DO NOT OPEN
ADVERTISSEMENT: RISQUE DE CHOC ELECTRIQUE-
NE PAS OUVRIR
Example of Antenna Grounding 
as per National Electrical Code 
Example of Antenna Grounding 
as per National Electrical Code 
Antenna lead in wire
Antenna lead in wire
Grounding Conductors
(NEC Section 810-71)
Grounding Conductors
(NEC Section 810-71)
Ground clamps
Ground clamps
Electric service
equipment
Electric service
equipment
Power service grounding electrode system
(NEC ART 250, Part H)
Power service grounding electrode system
(NEC ART 250, Part H)
Antenna discharge unit
(NEC Section 810-20)
Antenna discharge unit
(NEC Section 810-20)
Ground clamps
Ground clamps
QUADII Classic Manual 0405 Issue 2