Jeff Rowland Design Group 1 Manuel D’Utilisation

Page de 6
1. Check the rail fuses; on the Model 1, these are located on the inside of the amp 
adjacent to the encapsulated transformer. A fuse can often look good even if it is 
actually bad. If possible, check the fuses with a meter.  
2. If the fuses are good, disconnect the inputs from the amp and see if it will power up 
again. Your amplifier will generally only shut down if it senses DC, thus protecting your 
speakers. Certain associated equipment can occasionally pass DC.  
If the above suggestions do not work or you are having other problems,  
please contact your Jeff Rowland Design Group dealer.  
Technical Specifications 
  
                                                   
 Model 1 
 
Output power  
 
60 watts RMS continuous, 8 ohms  
120 watts RMS continuous, 4 ohms  
215 watts RMS continuous, 2 ohms
 
Power Bandwidth 
 
0.3 Hz to 300 kHz, -3 dB 
 
Slew Rate
 
70 volts per microsecond 
 
THD and Noise
 
Less than .025%, 1 kHz, 8 ohms, 20 watts  
Less than .035%, 1 kHz, 8 ohms, 60 watts
 
Damping Factor 
 
Greater than 200, 20 Hz to 20 kHz, 8 ohms 
Greater than 85 100 kHz, 8 ohms
 
Output Current
 
22 amps peak, continuous  
55 amps peak, 0.1 ohm, 20 msec, 1 kHz 
 
Overall Gain
 
Selectable: 20, 26, 29.5, 32 dB 
 
Sensitivity  
 
136 mV, 1 watt, 8 ohms
 
Input Impedance 
 
Selectable: 100k, 20k, 600 ohms 
 
Common Mode Rejection Ratio
 
Greater than 90 dB