Classe Audio CT-2300 Manuel D’Utilisation

Page de 34
27
Care and Maintenance
To remove dust from the cabinet of your amplifier, use a feather duster or a lint-
free soft cloth. To remove dirt and fingerprints, we recommend isopropyl alcohol
and a soft cloth. Dampen the cloth with alcohol first and then lightly clean the 
surface of the amplifier with the cloth. Do not use excessive amounts of alcohol 
that might drip off the cloth and into the amplifier.
 
Caution! 
At no time should liquid cleaners be applied directly to 
the amplifier, as direct application of liquids may result 
in damage to electronic components within the unit.
From time to time, the air intake filter will need to be vacuum cleaned or 
removed and rinsed with clean fresh water. A pressure sensor measures the 
airflow to determine when it is necessary to clean the filter. When cleaning is 
required, the Standby LED will flash (combined red/blue) and a message will 
be sent to connected touchscreen controlled devices via the connected CAN-Bus
system. Since this is a maintenance and not a protection feature, the amplifier 
will continue to operate while the LED is flashing, so as not to interrupt a 
listening session. Once the amplifier enters standby mode it will require reset to 
operate normally (press and hold the standby button). Use this opportunity to 
check and clean the air intake filter. Remove the front panel (CT series amps) or
the air intake cover (Delta series amps) to access the filter.