Amplifier at rated conditions, both channels driven, 8 
Ω loads, unless otherwise specified.
Depending on the ambient temperature, the unit might not operate continuously at 2 
Ω load in Normal Mode or 4 Ω in Bridged Mode.
Load Impedance
2
Ω
4
Ω
8
Ω
Maximum Midband Output Power
THD = 1%, 1 kHz, Dual Channel
3500 W
2500 W
1500 W
Rated Output Power
THD < 0.1%, 20 Hz...20 kHz
-
2100 W
1050 W
Maximum Single Channel Output Power
Dynamic-Headroom, IHF-A
4500 W
3200 W
1800 W
Maximum Single Channel Output Power
Continuous, 1 kHz
4100 W
2700 W
1600 W
Maximum Bridged Output Power
THD = 1%, 1 kHz
-
7000 W
5000 W
Maximum RMS Voltage Swing
THD = 1%, 1 kHz
125 V
Power Bandwidth
THD = 1%, ref. 1 kHz, half power @ 4 
Ω
10 Hz...50 kHz
Voltage Gain, ref. 1 kHz
41 dB / 35 dB / 32 dB (switchable)
Input Sensitivity 
rated power @ 8 
Ω, 1 kHz
0 dBu / +6 dBu / +9 dBu (switchable)
THD at rated output power 
MBW = 80 kHz, 1 kHz
< 0.05%
IMD-SMPTE 
60 Hz, 7 kHz
< 0.05%
DIM30 
3.15 kHz, 15 kHz
< 0.02%
Maximum Input Level
+22 dBu  (9.75 V
rms
)
Crosstalk 
ref. 1 kHz, at rated output power
< -80 dB
Frequency Response ref. 1 kHz
< 10 Hz...30 kHz (±1 dB)
Input Impedance active balanced
20 k
Ω
Damping Factor 1 kHz
> 400
Slew Rate
35 V/
μs
Signal to Noise Ratio Amplifier
A-weighted, 32 dB constant gain
111 dB
Output Noise, A-weighted
< -70 dBu
Output Stage Topology
Class H Grounded Bridge (3-stage)
Power Requirements
100-240 V, 50-60 Hz / 100 V, 50-60 Hz
Power Consumption
1/8 maximum output power @ 4 
Ω
1450 W
Protection
Audio Limiters, High Temperature, DC, HF, Short Circuit, Back-EMF, 
Peak Current Limiters, Inrush Current Limiters, Turn-on Delay, Mains 
Circuit Breaker Protection, Mains Overvoltage Protection
Cooling
Front-to-Rear, 5-Stage-Fans
Ambient Temperatur Limits
+5 °C...+40 °C (40 °F...105 °F)
Safety Class
I
Dimensions (W x H x D), mm
483 x 88.1 x 497.5
Weight
14.5 kg (32.0 lbs)