500 Watts
mono amplifier
Welcome!
This owners manual is written in easy english and
uses a lot of drawings to simply the installation and
use of the above amplifier.
Your DLS amplifier must be installed correctly in or-
der to work well. This manual will show you how to
install the amplifier like a pro. Please read the entire
manual before beginning the  installation.
Install the amplifier yourself if you feel confident  with
our instructions and if you have the proper tools.
However if you feel unsure, turn over the installation
job to someone better suited to it.
Warranty Service
This amplifier  is covered by warranty, depending on
the conditions in the country where it is sold. If the
amplifier is returned for service, please include the
original dated receipt with the product.
 
 
 
 
 
 Technical Assistance
For technical assistance ask the shop where the
product was sold or the distributor in your very coun-
try.
You can always phone the DLS Helpdesk in Sweden
+ 46 31 84 00 60 or send an e-mail to info@dls.se.
Information can also be found on our WEB-site
www.dls.se
Contents
Specifications................................
1
Features……………………………..
2
Installation…………………….…….
2
Trouble-shooting……………………
2
Tools and materials needed……….
3
Amplifier installation kit…………....
3
Routing Wires……………………....
3
Wiring
Power and Outputs……………..….
4
Inputs and controls………………...
5
Input level control..........................
5
Crossovers…………......................
5
Phase control.....………………...…
6
Speaker wiring.............………….….
6
Testing..........................................
6
Professional tips……………………..
7
Specifications
DLS CLASSIC
CA12
Number of channels
1
Power output:
R.M.S. output in 4 ohm (0,1% THD)
1 x 220 W
R.M.S. output in  2 ohm (0,4% THD)
1 x 400 W
R.M.S. output  in 1 ohm (0,5% THD)
1 x 500 W
All above output power ratings at 13,8 Volt
Signal to noise ratio, A-weighted
>100 dB
Damping factor
>100
Frequency response
10 Hz - 35 kHz
Input impedance, low level
10 kohm
Input impedance, high level
100 ohm
Input  sensitivity
0,25 - 5V
RCA output
yes
Phase control 0-180 degrees variable yes
Filter subsonic
15 - 150 Hz
Filter lowpass 12/24 dB slope
50 - 500 Hz
Power consumption, idle
0,8 A
Maximum current draw
80 A
Built-in fan cooling in bottom plate
yes
Fuse
2 x 30A
Dimensions (mm)
67x295x250
Dimensions (inch)
2,63x11,6x9,84
Weight
3,8 kg (8,4 lb)
We follow a policy of continuous advancement in
development. For this reason all or part of specifications
& designs may be changed without prior notice.
DLS Svenska AB
P.O. Box 13029
S-40251 Göteborg, Sweden
Tel: +46 31 840060
Fax: +46 31 844021
E-mail: info@dls.se
www.dls.se
Approval of electromagnetic compatability according
to the EEC Directive 95/54/EC
 E 13