Crown Audio CTs 1200 Manuel D’Utilisation

Page de 167
a. Connect the audio common leads (-) to the speaker’s
common terminal (marked COM). Refer to figures 2
and 3.
b. Connect the audio positive (+) leads to the + (SIG)
terminal.
c. Carefully reinstall housing cover using eight 5/16-18
x 1-3/4" hex head bolts, lockwashers and hex nuts
that were previously removed. Verify that all housing
and mounting bolts have been securely tightened.
WARNING
Property damage, serious injury, or death could occur if the
housing is not closed properly. To reduce possibility of
explosion, housing cover must be kept tight (all eight
bolts fully tightened) while circuits are energized.
WARNING
Audio wires should be sized properly by your licensed
installation electrician for your service application. This cable
requires a twisted shielded pair with an 18AWG mimum and
should produce no more than 15% signal loss over the
length of the cable run.
D.Testing/Operating.
WARNING
Under certain conditions these devices are capable of
producing sounds loud enough to cause hearing damage.
Adequate hearing protection should be worn if standing
within close proximity to device while testing. Recommenda-
tions in the OSHA Sound Level Standard
(29 CFR 1910) should not be exceeded.
1. After installation is complete, be sure to test the system
to verify that each speaker operates satisfactorily. If it
is found that the unit is too loud for its location, a
lower wattage tap may be selected. Carefully remove
the housing cover and move the speaker internal green
or red lead to a lower wattage tap (see figure 3).
Reinstall the housing cover and retest.
WARNING
Property damage, serious injury, or death could occur if the
housing is not closed properly. To reduce possibility of
explosion, housing cover must be kept tight (all eight bolts
fully tightened) while circuits are energized.
2. After completion of initial system test, establish a
program for periodic testing of this device. Refer to the
authority having jurisdiction for this information.
3. Provide a copy of these instructions for the Safety
Engineer, system operator(s) and maintenance person-
nel.
SAFETY MESSAGE TO OPERATORS
Even if your warning system is operating properly, it may not
be completely effective. People may not hear or heed your
warning signal. You must recognize this fact and ensure that
your warning signal achieves its intended effect through
proper test/training sequences within your specific
application(s).
E.Maintenance.
SAFETY MESSAGE TO MAINTENANCE
PERSONNEL
Failure to follow all safety precautions and instructions
may result in property damage, serious injury, or death to
you or others.
• Read and understand all instructions before performing
maintenance on this unit.
• Do not perform maintenance on this unit when circuits are
energized.
• Periodic checks should be made to ensure that effectiveness
of this device has not been reduced because speaker has
become clogged with a foreign substance or because
objects have been placed in front of the speaker.
• Any maintenance to this unit MUST be performed by a
trained electrician in accordance with NEC guidelines and
local codes.
• Never alter this unit in any manner. Safety in hazardous
locations may be jeopardized if additional openings or
alterations are made to this device.
• The nameplates, which contain cautionary or other infor-
mation of importance to maintenance personnel, should not
be obscured if exterior of device is painted.
WARNING
Effectiveness of explosion-proof enclosure must be
maintained. Use caution to avoid damaging machined
surfaces.
290A3831-02
BLK
RED
+
-
SPEAKER
SIGNAL SOURCE
SPEAKER
MODEL
AM30XD1
Figure 2. Typical Installation Wiring.
Figure 3. Internal Multi-tap Wiring Set-up.
290A3831-03
FIELD COMMON (-) LEADS TO
COMMON TERMINAL.
FIELD POSITIVE (+) LEADS TO  (+)
TERMINAL.
SPEAKER INTERNAL GREEN OR RED
LEAD TO BE CONNECTED TO (SIG)
TERMINAL.
SIG(+)