CONDITION: Power indicator is off.
POSSIBLE REASON
The amplifi er has lost AC power.
The amplifi er’s Power switch is off.
The amplifi er is not plugged into the 
power receptacle.
The amplifi er output level is so high that 
the power supply fuse has blown. Verify 
that input levels and output impedances 
are within safe ranges. Refer the unit to 
an authorized Crown service center for 
fuse replacement.
CONDITION: Power indicator is
fl ashing
.
POSSIBLE REASON:
The AC line voltage has dropped below 
10% or has risen above 10% of the
nominal line voltage of the power supply.
Refer to section 5.1.6 for specifi c voltage 
requirements.
CONDITION: Fault indicator is on.
POSSIBLE REASON:
The amplifi er channel has stopped 
oper ating. Return the unit to an 
authorized Crown Service Center.
CONDITION: Distorted sound.
POSSIBLE REASON:
 Load is wired incorrectly or Dual/Bridge 
mode switch is set incorrectly. Check 
both.
Input is overloaded by a signal level that is 
too high. Turn down your amplifi er level 
controls, or turn down the input sig nal, 
until the clip light goes out.
Thermal Level Control (TLC) is active.
Note: If the signal sounds distorted even 
though the Clip LED is off, the input signal is 
distorted. Check gain staging and output 
lev els of the mixer or preamp. 
6 Troubleshooting