Novatel DL-V3 Manuel D’Utilisation

Page de 208
DL-V3 User Manual Rev 3
 101
Message ID = 755
 Table 30:  Parameter Update
Field
Field Type
Bytes
Format
Units
Offset
1
Header
-
-
0
2
Parameter update, see Table 30
4
Enum
-
H
3
Group name
12
Char[ ]
-
H+4
4
Port to configure. 
(default = THISPORT)
SeTable 17 on Page 87
4
Enum
-
H+16
5
;Communication baud rate (bps).
A value of '0' indicates that no 
GROUPCOMCONFIG specification is associated 
with the port for the specified group. 
Possible bps values:
300, 600, 900, 1200, 2400, 4800, 9600, 19200, 
38400, 57600, 115200, or 230400
4
ULong
bps
H+20
6
4
Enum
-
H+24
7
Number of data bits 7 or 8
(default = 8)
4
ULong
-
H+28
8
Number of stop bits 1 or 2
(default = 1)
4
ULong
-
H+32
9
4
Enum
-
H+36
10
Echo
0 = Off - No echo
1 = On (default) - Transmit any input characters as 
they are received
4
Enum
-
H+40
11
Break 
0 = Off - Disable break detection
1 = On (default) - Enable break detection 
4
Enum -
H+44
Binary
ASCII
Description
0
DEFAULT
Set the parameter for a group to the default (default)
1
SET
Set parameter for a the group
2
CLEAR
Clear a parameter from the group