Mitsubishi Electronics MR-J3 Manuel D’Utilisation

Page de 668
 
 
6 -  31 
6. PARAMETERS 
 
No.  Symbol 
Name and function 
Initial 
value 
Unit 
Setting 
range 
PD03 
 
*DIA3  Input signal automatic ON selection 3 
Select the input devices to be automatically turned ON. 
 part is for manufacturer setting. Do not set the value by any means. 
0
Initial value
BIN
HEX
Device name
0
Automatic/manual
selection (MD0)
0
0
0
0 0 0
BIN 0: Used in CC-Link or as external
           input signal.
BIN 1: Automatic ON
 
0000h   Refer 
to 
name and 
function 
column. 
PD04 
 
*DIA4  Input signal automatic ON selection 4 
Select the input devices to be automatically turned ON. 
0
0
Initial value
BIN
HEX
Device name
Point table No.
selection 2 (DI1) 
0
BIN 0: Used in CC-Link or as external
           input signal.
BIN 1: Automatic ON
0
0
Point table No.
selection 1 (DI0)
Point table No.
selection 3 (DI2)
Point table No.
selection 4 (DI3) 
0
0
Initial value
BIN
HEX
Device name
Point table No.
selection 6 (DI5)
0
0
0
Point table No.
selection 5 (DI4) 
Point table No.
selection 7 (DI6)
Point table No.
selection 8 (DI7)
0 0
 
0000h   Refer 
to 
name and 
function 
column. 
PD05 
 
 
 
For manufacturer setting 
Do not change this value by any means. 
0000h