Mitsubishi Electronics MR-J3 Manuel D’Utilisation

Page de 668
 
 
7 -  15 
7. MR Configurator 
 
7.7.2 Positioning operation 
POINT  
The servo motor will not operate if the forced stop (EMG), forward rotation 
stroke end (LSP) and reverse rotation stroke end (LSN) are off. Make 
automatic ON setting to turn on these devices or make device setting to 
assign them as external input signals and turn on across these signals and 
DOCOM. (Refer to section 7.6.) 
When an alarm occurs, the positioning operation is automatically canceled. 
 
Click "Test" on the menu bar and click "Positioning" on the menu. 
 
Clicking displays the confirmation window for switching to the test operation mode. 
 
Click the "OK" button to display the setting screen of the Positioning operation. 
During the servo on, the confirmation window indicating that the next operation is in the stop status is 
displayed. 
 
After confirming that the operation is in the stop status, click the "OK" button to display the setting screen for 
the positioning operation.