TOA Electronics VM-2120 Manuel D’Utilisation

Page de 72
46
Function/status 
When communications cannot be achieved
between the RM-200M and the VM amplifier
or between VM amplifiers (High state when
communications are restored.) 
When the FAULT indicator lamp is on 
When an Emergency broadcast is performed
by the VM amplifier or the external equipment.
(See the description of Pin 8 VM amplifier's
broadcast cutoff.) 
When the EV-200 Voice Announcement
Board fails.*
1
Pin 
No. 
22 
23 
24 
25 
Signal name 
Communications error 
Failure indication 
Emergency broadcast
on 
EV-200's failure 
IN
/OUT 
OUT 
OUT 
OUT 
OUT 
Signal/logic 
Active Low 
Active Low 
Active Low 
Active Low 
*
1
Requires installation of the optional EV-200 Voice Announcement Board. 
*
2
Use this pin to cut off the VM amplifier's power amplifier output to allow the "Emergency broadcast" initiated
by connected external equipment to go through. 
[Electrical characteristics] 
Input 
Open voltage:
3.3 V DC 
Short-circuit current: Under 1 mA 
Activation: 
No-voltage make contact (one-shot signal is shown below.) 
Output 
Circuit:
Open collector (See below.) 
Withstand voltage: 30 V DC 
Control current:
Under 10 mA 
Over 100 ms
Control current