GE DR-1200 Manuel D’Utilisation

Page de 24
Adjusting the Camera 
Rugged Dome Installation Manual 
 
18 
1038346B / February 2003 
4.3 A
UTO 
I
RIS 
L
ENSES
 
For auto iris lenses, use an insulated adjustment tool to adjust the DC 
level with the blue pot on the PC assembly (Figure 14). Proper 
adjustment will ensure the correct exposure depending on the camera’s 
situation and the lighting levels.  
To set the light level at which the camera switches between daylight and 
IR mode, see Figure 14 and perform the following. 
 
• 
For brighter light conditions, turn the DC auto iris level adjustment 
pot counterclockwise. 
• 
For lower light conditions, turn the DC auto iris level adjustment pot 
clockwise. 
 
DC auto iris level 
adjustment pot 
 
 
 
 
 
 
 
 
 
Figure 14. Adjusting the DC level on the PC assembly