22    Installing the Genie Camera 
Genie Monochrome Series-GigE Vision Camera 
Status LED Codes 
The camera is equipped with a LED to display the operational status of the camera. When more than one condition 
is active, the LED color indicates the condition with the highest priority (such as an acquisition in progress has more 
priority than a valid IP address assignment). The following table summarizes the LED states and corresponding 
camera status.  
 
LED State 
Definition 
LED is off 
No power to the camera 
Steady Red 
Camera not initialized 
Slow Flashing Red 
Camera initialization problem 
Fast Flashing Red 
Camera is too hot 
Slow Flashing Blue 
Waiting for an IP address 
Fast Flashing Blue 
Ethernet cable disconnected (no link)  
Steady Blue 
IP address assigned; 
no application connected to the camera 
Steady Green  
Application connected  
Slow Flashing Green 
Triggered acquisition in progress 
Fast Flashing Green 
Free-running acquisition in progress 
 
Once the Genie has its RJ45 connected to a network, the Status LED will turn to steady blue when the IP address is 
assigned. Only at this time will it be possible by the GigE Server or any application to communicate with the 
camera. 
 
 
Note: Even if the Genie has obtained an IP address, it might be on a different subnet than the NIC it is attached to. 
Therefore, if the Genie LED is blue but an application such as CamExpert can not see it, this indicates a network 