Siemens CCMX1315-LP Manuel D’Utilisation

Page de 60
Camera part and connector definition 
12 
Siemens Building Technologies
 
 
Fire Safety & Security Products 
 
01.2009
 
 
5.2 
Connector pin definition 
5.2.1 
Digital I/O terminal 
 
GND 
AI2 
1. 
External alarm input-2 
2. 
Becoming BW/CL enforced input when the Digital 
Input Mode is set to BW Mode in the Configuration-
Alarm
 page 
RS485- / + 
RS485 signal output port for telemetry control 
COM 
AO  
Alarm output port 
GND 
 
Al1 
External alarm input-1 
5.2.2 
DC Auto Iris port 
 
PIN 1 
Damp - 
PIN 2 
Damp + 
PIN 3 
Drive + 
 
PIN 4 
Drive  
5.2.3 
Power IN connector 
 
RED: Power + 
 
WHITE: Power - 
Power: 12 V DC or 24 V AC 
5.2.4 
Video output connector 
 
 
Video Signal Output 
Composite video output 
5.2.5 
IP/TV switch 
 
IP 
Video out through Ethernet 
 
TV 
BNC composite video out for installation purposes
 
5.2.6 
Default/reset buttons 
 
DEFAULT
 
Return to factory default by pressing button for 5 
seconds 
 
RESET
 
System re-start