Siemens CCIC1410 Manuel D’Utilisation

Page de 96
Configuration with the CCIC1410 Homepage 
55 
Siemens Building Technologies
 
 
Fire Safety & Security Products 
 
05.2009
 
 
9.7.2 HTTP 
 
1. 
Open the CCIC1410 Homepage (see chapter 9.1). 
2. 
Choose the Configuration menu. 
3. 
On the left hand side, choose the menu item Network
4. 
Define the settings. 
5. 
Click Save
 
Authentication 
Depending on your network security requirements, the network camera provides 
two types of security settings for an HTTP transaction: basic and digest
If basic authentication is selected, the password is sent in plain text format; there 
is a potential risk of being intercepted. 
If digest authentication is selected, user credentials are encrypted in MD5 
algorithm and thus provide better protection against unauthorized accesses. 
Primary stream port / Secondary stream port  
The primary and the secondary stream are accessed via different port numbers. 
Please define the port numbers for each video stream according to your network 
requirements. 
The port number can be assigned between 80 and 65535. If the ports are 
incorrectly assigned, a warning message will be displayed. 
Stream name: 
Access name for stream 1 or stream 2. 
If port of motion jpeg stream 1 is 80, the cgi to request stream 1 is 
If port of motion jpeg stream 2 is 81, the cgi to request stream 2 is 
Please note that the stream name is the same for stream 1 and stream 2. 
The Web server will have the same ports as the motion jpeg streaming ports 
(stream1 and stream2). Actually, there are 2 ports for webpage access and the 
motion jpeg streaming server also uses these 2 ports for dual streams. They are 
linked and cannot be separated. 
 
 
 
 
 
NOTE 
To utilize the HTTP authentication, make sure that you have set a password for the network camera 
first. 
Microsoft® Internet Explorer does not support server push technology; therefore, using 
http://<ipaddress>:<http port>/<access name for stream1 or stream2> will fail to access the 
network camera.