JAI CV-M2 Manuel D’Utilisation

Page de 35
CV-M2
 
 
- 19 - 
 
 
6.4.2. Edge Pre-select Mode 
In EPS mode, the trigger leading edge will start an exposure at the first LVAL pulse if LS=0, (or 
immediately if LS=1), and it stops and the resulting image is read out after the pre-selected 
shutter time. It can be the 10 steps in normal or 1216 steps in programmable. SM=0 or SM=1. 
This mode will operate with full and partial scanning.  
An EEN pulse will indicate the active accumulation time, and a FVAL pulse indicates that the 
resulting video is read out. 
 
To use this mode:  
Set function: 
Trigger mode “Edge Pre-select”  
TR=1 
 
LVAL synchronous accumulation 
LS=0, LS=1 
 
Shutter mode “Normal” or “Programmable” 
SM=0, SM=1 
 
 
“Shutter Speed” 
SH=0 through 9 
 
“Programmable exposure” 
PE=1 through 1216 
 
Scanning format 
SC=0 through SC=4 
 
Output select 
OS=0, OS=1 
 
Polarity and other functions 
Input: 
Ext. trigger to Camera Link or pin 10 on 12-pin connector.  
 
 
Important notes on using this mode.
 
•  The duration of the trigger should be >2LVAL to <3FVAL. 
•  If LS=0 (Synchronous accumulation), the minimum trigger interval is 1 FVAL + 3 LVAL. The 
new exposure should not be finish before the previous frame is read out.  
•  If LS=1 (Asynchronous accumulation) the minimum trigger interval is the exposure time + 
3 LVAL. A new trigger must not be applied before FVAL is low. 
•  1LVAL = 47.9 µsec (single). 27.3 µsec (dual).  
 
 
For horizontal timing refer to 6.2.3 through 6.2.6. (Fig.17. through fig. 20.) 
For LVAL synchronous accumulation refer to 6.2.7 and 6.2.8. (Fig. 21. fig. 22.) 
 
LVAL
DATA  OUT
SUB
SG
FVAL
OB
1
Ef f ect i ve  Li nes
2L
2 3 4 5
11
97
11
96
11
98
12
00
11
99
1200L
4L
1214L
EEN
Ext . Tr i g1
4L
Re
se
rv
ed
4L
OB
Re
se
rv
ed
When  t he  LVAL  Sync  Accum.   :   1. 5L
DVAL
Exposur e
Per i od
When  t he  LVAL  Async  Accum. :   0. 5  t o  1. 5L
 
 
Fig.24. Edge Pre-select mode vertical timing