JAI CV-M50IR Manuel D’Utilisation

Page de 24
- 14 -
CV-M50IR
SW1-1
MSB
SW1-2
SW1-3
LSB
Shutter speed (sec.)
Normal shutter
Ext. trigger shutter
OFF
OFF
OFF
Off
1/60 (1/50)
OFF
OFF
ON
1/100
1/125
OFF
ON
OFF
1/250
OFF
ON
ON
1/500
ON
OFF
OFF
1/1000
ON
OFF
ON
1/2000
ON
ON
OFF
1/4500
ON
ON
ON
1/10,000
Switch no.
Switch function
Mode setting
OFF
ON
1
Shutter data MSB
For shutter speed select.
Refer to shutter table 7.1.3.
2
Shutter data
3
Shutter data LSB
4
Trigger select
Normal
Ext. trigger
5
CCD accumulation
Field accumulation
Frame accumulation
6
Scanning system
2:1 interlaced
Non-interlaced
7
Gamma correction
Gamma = 1.0
Gamma = 0.45
8
Gain
Manual gain
AGC on
7. Mode Setting
Caution on Mode Setting.
Before making any mode or jumper setting turn the power OFF.
7.1.1. SW1 Switch on the Rear Panel
Factory settings for SW1 are with all 8 switches in OFF position.
7.1.2. Table for SW 1 Setting
7.1.3. Table for Shutter Time
Caution on Shutter.
The image can flicker when the illumination is AC powered.
Highlighted parts of the image will show increasing smear at a shorter shutter time.
OFF = <
ON = >
1/50
off
1/100 1/250 1/500 1/1000 1/2000 1/4500 1/10,000
<
<
<
<
<
>
<
>
<
<
>
>
>
<
<
>
<
>
>
>
<
>
>
>
OFF
ON
1
2
3
4
5
6
7
8
GAIN
INTERLACE
TRIGGER
SHUTTER
GAMMA
ACCUMM
Interlaced < > Non-interlaced
Normal < > External trigger
1.0 < > 0.45
Manual < > Auto
Field < > Frame
Seconds
SW1