6.2.5. Timing for window of interest 
With WS=1, the X and Y start coordinates (WX and WY), and the width and height (WW and WH) 
for the window of interest can be programmed with 1 pixel interval. The minimum window size 
is 2(h) x 3 (v). If the window is specified outside the full image area, it will be placed up to the 
right or low limit as shown in fig 17. right. 
 
Figures marked with (*) in the timing diagrams below will change with other window settings. 
 
(0, 0) 
(658, 492)
Active Pixel Array 
659 
493 
120 
240 
(200, 100) 
(0, 0) 
(658, 492) 
Active Pixel Array 
659 
493 
100 
100 
(559, 393) 
Readout Region 
(WX=559, WY=393, WW=100, WH=100) 
Specifyed Region 
(WX=600, WY=400, WW=100, WH=100) 
 
Fig. 17. Window of interest. 
 
 
1 LVAL = 16.825 µs 
 
LVAL
DATA  OUT
FVAL
Ef f ect i ve  Li nes
21
6
21
5
……
120L( *)
125L( *)
129L( *)
……
1  FVAL  per i od
21
7
21
9
21
8
DVAL
4L
……
5L
4L
10
0
10
1
10
2
10
3
10
4
10
0
10
1
10
2
10
3
10
4
( *)   Var i abl e  Number
 
Fig. 18. Vertical timing for window of interest. 
 
 
 
DATA  OUT
LVAL
Ef f ect i ve  Pi xel s
……
240ck( *)
668ck
673ck
1  LVAL  per i od
DVAL
5ck
9ck
9ck
5ck
200ck( *)
43
7
43
8
43
9
20
0
20
1
20
2
……
219ck( *)
( *)   Var i abl e  Number
 
1 ck = 25 nsec 
Fig. 19. Horizontal timing for window of interest.