JAI CV-A33CL Manuel D’Utilisation

Page de 26
CV-A33CL
 
 
- 20 - 
   
 
7.3. CV-A33CL command list 
 
Command Name 
Format 
Parameter 
 
Remarks 
      A – General settings and useful commands 
EB 
Echo Back 
EB=[Param.]<CR><LF> 
0=Echo off 
1=Echo on 
Off at power up 
ST 
Camera Status request 
ST?<CR><LF> 
 
 
Actual setting 
HP 
Online Help request 
HP?<CR><LF> 
 
 
Command list 
VN 
Firmware version 
VN?<CR><LF> 
 
 
3 letter version 
ID 
Camera ID request 
ID?<CR><LF> 
 
 
10 characters 
MD 
Model Name request 
MD?<CR><LF> 
 
 
≤ 10 characters 
UD 
User ID (Free text) 
TR=[Param.]<CR><LF> 
User can save and load free text 
≤ 16 characters 
      B – Video Output
 
BA 
Output bit allocation 
BA=[Param.]<CR><LF> 
0=10 bit 
1=8 bit 
Camera Link 
 
 
 
 
 
 
      C – Timing and shutter related commands 
WS 
Windows Scan 
WS=[Param.]<CR><LF> 
0=full frame 
1=windows scan 
 
WX 
X Scan start coordinate 
WX=[Param.]<CR><LF> 
0-657  
Start pixel # 
WY 
Y Scan start coordinate 
WY=[Param.]<CR><LF> 
0-490  
Start line# 
WW 
X Scan size width 
WW=[Param.]<CR><LF> 
2-659  
Window width 
WH 
Y Scan size height 
WH=[Param.]<CR><LF> 
3 – 493 
 
Window height 
AT 
Auto Trigger  
AT=[Param.]<CR><LF> 
3-493  
*) 
Wind. 3H to 493H 
TR 
Trigger mode 
TR=[Param.]<CR><LF> 
0=normal 
2=Pulse width 
1=Edge pre-sel 
3=Auto Trigger 
 
SM 
Shutter mode 
SM=[Param.]<CR><LF> 
0=Normal 1=Program. 
exp 
 
SH 
Shutter speed 
SH=[Param.]<CR><LF> 
0=Off (1/120) 
2=1/500 
4=1/2000 
6=1/10000 
1=1/250 
3=1/1000 
5=1/5000 
7=1/20000 
All 8 steps are 
valid in normal 
trigger mode. 
 
PE 
Programmable expos. 
PE=[Param.]<CR><LF> 
2-493  
Exp. 1H to 492H 
H= 16.8µsec 
      D– Signals and polarity 
LS 
LVAL synchronous accum. 
LS=[Param.]<CR><LF> 
0= LVAL sync. 
1= 
LVAL a-sync.
 
*1) Only a-sync. 
TI 
Trigger Input 
TI=[Param.]<CR><LF> 
0= CamerLink 
1= 12 pin Hiror 
 
TP 
Trigger polarity 
TP=[Param.]<CR><LF> 
0= active low 
1= active high 
*2) 
     E – Gain and analogue signals setting 
BL 
Black level  
BL=[Param.]<CR><LF> 
0-31 
(0=low 31=high)
 
 
 
 
 
 
 
GA 
Gain level  
GA=[Param.]<CR><LF> 
1-11 
(0=low 11=high) 
 
CB 
Calibration of CMOS sensor  CB=0<CR><LF> 
0 is the only allowed parameter 
Will calibrate the 
CMOS sensor 
     F – Saving and loading data in EEPROM 
LD 
Load settings from camera 
EEPROM 
LD=[Param.]<CR><LF> 
0=Factory data  
2=User 2 area 
1=User 1 area 
 
Latest used data 
default at power 
up 
SA 
Save settings to camera 
EEPROM 
SA=[Param.]<CR><LF> 
1=User 1 area 
 
2=User 2 area 
Parameter = 0 is 
not allowed 
*) 
Auto trigger window will always start from top. Max frame rate with AT=3. It is 2 LVAL exposure + 9 LVAL offset. 
*1) 
The command LS is found on the first cameras. Only LS=1 is will work correct.  
*2) 
If positive logic is used (TP=1), the first trigger pulse after power up will be ignored. TTL only. 
 
!! 
Do not try to use commands not shown in this list.