Lucent Technologies 8.2 Manuel D’Utilisation
DEFINITY ECS Release 8.2
Administrator’s Guide
Administrator’s Guide
555-233-506
Issue 1
April 2000
Screen reference
822
Modem Pool Group
17
Circuit Pack Location
Enter the port associated with the conversion resource on the integrated modem
pool circuit pack.
pool circuit pack.
For example, 01A0612 is in cabinet 01, carrier A, slot 06, and circuit number
(port) 12.
(port) 12.
PORT PAIR ASSIGNMENTS
are optional on “combined” pooled modem screens
only.
Analog Digital
Enter the port numbers of the modem/TDM pair in a conversion resource.
NOTE:
Two port entries are required.
For example, 01A0612 is in cabinet 01, carrier A, slot 06, and circuit number
(port) 12.
(port) 12.
Valid entries
Usage
01
through
22
First and second characters are the cabinet number
01
through
03
01
(G3s)
A
through
E
Third character is the carrier
01
through
20
Fourth and fifth characters are the slot number
01
through
32
Sixth and seventh characters are the circuit number
Valid entries
Usage
01
through
22
First and second characters are the cabinet number
01
through
03
01
(G3s)
A
through
E
Third character is the carrier
01
through
20
Fourth and fifth characters are the slot number
01
through
32
Sixth and seventh characters are the circuit number