9-408
CLSFY-PT (Call Classifier Port)
9
Tone Detector Audit/Update Test (#43)
This test performs a sanity audit on the CLSFY-PT (Call Classifier Port).
1-3
FAIL
DTMF digits were not detected correctly. This may or may not impact
reception of R2-MFC calls.
reception of R2-MFC calls.
1. Run the short test sequence via the test port UUCSSpp sh r 1
command.
2. If the problem persists, the system is still operating properly but
capacity will be reduced. To restore performance to normal, replace the
call classifier circuit pack containing the defective CLSFY-PT (Call
Classifier Port).
call classifier circuit pack containing the defective CLSFY-PT (Call
Classifier Port).
102
FAIL
2225 Hz Modem Answer Tone was not detected correctly. This will impact
call-classification operation.
call-classification operation.
1. Run the short test sequence via the test port UUCSSpp sh r 1
command.
2. If the problem persists, the system can still operate properly but
capacity will be reduced. In order to restore performance to normal,
replace the call classifier circuit pack containing the defective port.
replace the call classifier circuit pack containing the defective port.
130
FAIL
Forward or backward R2-MFC signals were not correctly generated or
detected. This will impact R2-MFC calls.
detected. This will impact R2-MFC calls.
1. Run the short test sequence via the test port UUCSSpp sh r 1
command.
2. If the problem persists, the system can still operate properly but
capacity will be reduced. In order to restore performance to normal,
replace the call classifier circuit pack containing the defective port.
replace the call classifier circuit pack containing the defective port.
PASS
Tone detection verification is successful. The call classifier port is able to
detect and generate all necessary tones.
detect and generate all necessary tones.
Table 9-173.
TEST #43 Tone Detector Audit/Update Test
Error
Code
Code
Test
Result
Description/ Recommendation
none
ABORT
The system was not able to allocate the resources for this test.
1. Retry the command at 1-minute intervals for a maximum of 5 times.
Continued on next page
Table 9-172.
TEST #42 Tone Detection Verification Test — Continued
Error
Code
Code
Test
Result
Description/ Recommendation