Lucent Technologies Release 7 Manuel D’Utilisation

Page de 2657
DEFINITY Enterprise Communications Server Release 7 
Maintenance for R7r  
555-230-126  
Issue 4
June 1999
Maintenance Object Repair Procedures 
9-1300
PNC-DUP (PNC Duplication) 
9
Screen 9-1.
Status PNC Screen with Standby PNC Fully In-Service
PNC State of Health Indexes
The Inter-PN and Inter-SN Indexes form the state of health vector, which is used 
to track and compare the states of health of both PNCs. The fields making up the 
indexes are two digit numbers separated by periods (.), with each field 
representing a different class of faults. The fault class fields are arranged in order 
of decreasing importance from left to right. In other words, each field in the index 
supersedes the following fields in determining which PNC is healthiest. A fault 
class drives an interchange only when all of the higher priority fault classes are 
equal. A zero entry indicates no faults in that class. Increasing numbers indicate 
increasingly higher numbers of faults present in that class.
The Inter-PN Index contains five fields (XX.XX.XX.XX.XX), and the Inter-SN Index 
has two (XX.XX). The Inter-PN Index reports faults in connectivity between port 
networks and supersedes the Inter-SN Index, which reports faults in connectivity 
between switch nodes. (The Inter-SN Index is only meaningful for systems with a 
center stage switch having 2 switch nodes, each of which is duplicated).
The meaning of each fault class field is given in the following table. A zero entry 
indicates that there are no such faults reported. Higher numbers indicate 
increasing number of faults. All zeros indicates perfect state of health. Unless the 
PNCs are locked, the active PNC’s state of health should always be equal to or 
better than the standby’s. (Otherwise, the system would perform a spontaneous 
interchange.)
status pnc                                                   page 1 of 1
                           PORT NETWORK CONNECTIVITY
                             Duplicated? yes
                        Software Locked? no
                         Standby Busied? no
                         Direct Connect? no
                      Standby Refreshed? yes
                   Interchange Disabled? no
              A-PNC                                B-PNC
           Mode: active                           Mode: standby
State of Health: functional            State of Health: functional
 Inter PN Index: 00.00.00.00.00         Inter PN Index: 00.00.00.00.00
 Inter SN Index: 00.00                  Inter SN Index: 00.00
   Major Alarms: 0                        Major Alarms: 0
   Minor Alarms: 0                        Minor Alarms: 0
 Warning Alarms: 0                      Warning Alarms: 0
   SN Locations: 01E                      SN Locations: 01D