June 1999
Maintenance Object Repair Procedures 
9-1541
STRAT-3 (Stratum 3 Clock) 
9
f. This error type corresponds to FAIL code 16 of the Stratum 3 Clock Alarm 
Query (test #649): all power supplies failed.
g. This error type corresponds to FAIL code 32 of the Stratum 3 Clock Alarm 
Query (test #649): all clock unit(s) failed.
h. An OFF-BOARD alarm on the Stratum 3 clock, indicates a DS1 facility 
problem; an ON-BOARD alarm indicates a fault in either the Stratum 3 
clock or the connection between the Stratum 3 clock and the switch. If the 
Stratum 3 clock cannot be referenced and the local oscillator on the 
TN780 Tone-Clock circuit pack must serve as the reference, a Major alarm 
is raised. Otherwise, a Minor alarm is raised.
i. This error can be caused by one of the following conditions:
One or both TOCs (Timing Output Cards) has failed.
The connection between the Stratum 3 clock and the TN780 
Tone-Clock circuit pack is faulty.
The TN780 Tone-Clock circuit pack is defective.
A Minor alarm results if the Stratum 3 clock can still provide timing to the 
switch; otherwise, a Major alarm will be raised because the Stratum 3 
clock is not providing timing and the switch is referencing the local 
oscillator on the TN780 Tone-Clock circuit pack. If only the Active TN780 
Tone-Clock circuit pack is faulty, the Standby TN780 Tone-Clock circuit 
pack becomes active and remains synchronized to the Stratum 3 clock. 
When the system switches to the Standby Tone-Clock circuit pack, the 
alarm is resolved, and a TDM-CLK alarm is raised to indicate a possible 
problem on the TN780 Tone-Clock.
If the alarm is minor:
Look for a red LED on either or both TOC cards. If there is a red LED, then 
replace the card. If there is no red LED, then, using the 
Stratum 3 Wiring 
Guide, check that the wiring installation is correct. After replacing the card 
or correctly rewiring the installation, clear the alarm by first issuing the 
disable synchronization-switch command followed by the enable 
synchronization-switch
 command. The latter procedure will cause 
synchronization software to switch back to using the Stratum 3 clock 
again. Wait 2 minutes and then execute the status synchronization 
command. If Maintenance Name on the status screen shows ‘‘STRAT-3,’’ 
then the problem is resolved.
!
CAUTION:
The disable synchronization-switch command followed by the 
enable synchronization-switch command may cause slip alarms. 
The circuit packs that can experience slips and the associated error 
log entry for slips are as follows.