Lucent Technologies Release 7 Manuel D’Utilisation

Page de 2657
DEFINITY Enterprise Communications Server Release 7 
Maintenance for R7r  
555-230-126  
Issue 4
June 1999
Maintenance Object Repair Procedures 
9-150
ATM-BCH (ATM B-Channel Trunk) 
9
Table 9-62.
ATM-BCH alarms by service state 
Service state
Alarm
1
1.
ATM-BCH alarms; alarms against other maintenance objects may also be present.
Possible cause
Possible solution
Out-of-Service/NE
Warning
Trunk busied out
Release the port (release trunk 
grp#/mbr#
).
Minor
NPE Crosstalk Test (#6) 
failed
Replace ATM circuit pack.
None
ATM circuit pack lost 
signal or there is a 
circuit pack problem.
Install circuit pack or cable. Check 
circuit pack using procedures in 
ATM-BCH. Check far-end switch 
status.
Out-of-Service/FE
Warning
Unadministered far-end
Administer the corresponding trunk 
on the far-end switch.
Warning
Far-end busied out
Check the status of the far-end 
switch.
Pending/In-Service
Pending/Maint
None
Maintenance message 
timed out waiting for 
reply
Wait 2 minutes after the pending 
state clears, and check the service 
state.
Maint/NE
None
ISDN test call in 
progress (test trunk 
long
)
Wait for the test to finish and 
recheck.
None
System link busied out
Check link status. Run release link 
link#.
Maint/FE
Warning
Signaling channel 
down for over 90 sec.
See 
Warning
Repeated lack of 
response to messages 
sent to the far end
Wait. Maintenance software resends 
messages periodically. Or run test 
trunk
 
grp#/mb# or test 
signaling-grp 
grp#.
Warning
The far-end trunk is 
being tested.
Check status of the far-end switch. 
Wait for testing to finish.
In-Service
None
Normal operating state
Continued on next page