Lucent Technologies Release 6 Manuel D’Utilisation
DEFINITY Enterprise Communications Server Release 6
Installation and Test for Multi-Carrier Cabinets
Installation and Test for Multi-Carrier Cabinets
555-230-112
Issue 5
May 1998
Test the System
Page 4-7
Test Duplicated Switch Processing Element Interchange
4
Test Duplicated Switch Processing
Element Interchange
Element Interchange
For high and critical reliability systems only.
1. Verify the screen displays:
Command:
2. Type status cabinet < 1-44> and press
Enter
.
3. Verify the screen displays test results similar to
Screen 4-6
.
Screen 4-6.
Example System Status Report for All Cabinets
4. Note the
MODE
of
SPE 1A
and
1B
.
5. Type refresh spe
and press
Enter
.
Command successfully completed
should be displayed.
6. Type reset system interchange
and press
Enter
. This causes the terminal
to log off.
7. Log in as craft again. Remember to use the new password established for
craft.
8. Note the
MODE
for
SPE 1A
and
1B
should have changed from that noted
in Step 4.