Pelco c3401m-a Manuel D’Utilisation

Page de 28
 
C3401M-A (1/06)
7
 
SWITCH SETTINGS
 
Coaxitron control:
 
 If you are going to use Coaxitron protocol to communicate with the dome system, you do not have to 
set any switches. Proceed to the installation instructions that follow this section.
 
Non-Pelco control:
 
 If you are going to install a protocol translator board to communicate with the dome system through 
a non-Pelco controller, proceed to the installation instructions that follow this section. When you are instructed to install 
the translator board, you will set the switches as described in the installation/operation manual that accompanies the 
translator board.
 
D or P control:
 
 If you are going to use D or P protocol to communicate with the dome system, follow the steps below to 
1. Place the  dome drive on a flat surface with the dome liner pointing up.
2. Point the camera straight up.
3. Using a flashlight, look straight down through the viewing slot of the dome liner. Look at the circuit board in the 
bottom of the housing. Rotate the dome liner until you see two DIP switches on the circuit board.
 
 
NOTE:  
 
The unit automatically detects D or P protocal.
 
Figure 2.  
 
Component Locations
 
DATA PORT
 
 
Software/Language File Upload
 
 in the Operation/
Programming manual.
 
WARNING:  
 
Do not remove the dome liner (refer to Figure 2). Replacing the dome liner requires qualified service 
personnel; otherwise, the dome drive may not operate properly.
SW 3
SW 2
ON
ON
REMOTE
DATA
PORT
DOME
LINER