Pelco TI2550 Manuel D’Utilisation

Page de 28
C1309M-A  (9/08)
15
Configuration
The camera setup must be complete before the camera can be configured (refer to Setup on page 7).
To open the TI25 GUI configuration software, on your PC go to Start >Programs>Pelco>TI25 GUI.
CAMERA TAB
SAVE SETTINGS
After changing camera settings on any of the GUI tabs, click the Save Settings button to store the current sections as the new default settings. 
The next time that the camera power is cycled, these saved settings will remain as the defaults. If you do not click Save Settings, the changes 
made to the settings will remain only until power to the camera is turned off. Cycling power will cause the camera to revert to the previously 
saved settings.
FACTORY DEFAULTS
Click the Factory Defaults button to restore the camera's settings to the Pelco factory defaults.
If you want the factory default settings to be saved even after the camera power is turned off, click Factory Defaults, and then click Save 
Settings.
RESET
Click the Reset button to restart the camera software; this function is nearly identical to cycling camera power.
FLAT FIELD CORRECTION
Flat Field Correction (FFC) controls how the camera regularly adjusts its thermal settings to optimize its image. This process takes about 
0.5 seconds. During this process, there may be a lag in image quality.
Before performing the FFC process, the camera warns the operator by displaying a small blinking box in the upper-left corner. This indicator 
appears for 2 seconds.
Adjust the FFC Interval or Temp Change settings to set the frequency of the FFC calibration sequence. While it is strongly discouraged, you can 
also turn off this feature by setting the AGC mode to Manual (refer to AGC Mode on page 20.)
The following sections describe how to use each FFC option (refer to Figure 6).
Figure 6. TI25 GUI Camera Tab