Installation
The TI2500 Series fixed-mount thermal imager can be mounted using an appropriate wall, ceiling, or pedestal mount (refer to the product 
specification sheet for a list of compatible mounts). For proper installation, refer to the instructions supplied with the mount. The enclosure 
should be attached to the mount by a minimum of two 1/4-20 fasteners (not supplied).
Table C and Table D show the recommended maximum distances for 24 VAC applications; the values are calculated with a 10 percent voltage 
drop. (Ten percent is generally the maximum allowable voltage drop for AC-powered devices.)
WARNINGS:
Do not install the thermal imager without the sun shield; doing so will void the product’s warranty.
Always use a service loop, as shown in Figure 10 and Figure 11 to further prevent water leakage.
During setup, keep the lens cover on the camera to avoid scratching the lens. Be sure to remove the lens cover after installation is 
complete.
Figure 10. Typical Fixed Wall Mounting
Figure 11. Typical Fixed Ceiling Mounting
Table C. 24 VAC Wiring Distances
Wire Gauge
M
aximum distance
 from 
transformer to lo
ad
Total
VA 
20 
(0.5 mm
2
)
18 
(1.0 mm
2
)
16 
(1.5 mm
2
)
14 
(2.5 mm
2
)
12 
(4.0 mm
2
10 
(6.0 mm
2
)
10 283 
(86)
451
(137) 
716 
(218) 
1142 
(348)
1811
(551) 
2880 
(877) 
20 141 
(42) 
225
 (68) 
358
 (109) 
571
 (174)
905
 (275) 
1440
 (438)
30 94
 (28) 
150
 (45)
238 
(72) 
380 
(115) 
603 
(183)
960 
(292)
40 70 
(21)
112 
(34) 
179 
(54) 
285 
(86) 
452 
(137) 
720 
(219) 
50 56 
(17) 
90 
(27) 
143 
(43) 
228 
(69) 
362 
(110)
576 
(175) 
Table D. Video Coaxial Cable Requirements
Cable Type*
Maximum Distance
RG59/U
750 ft (229 m)
RG6/U
1,000 ft (305 m)
RG11/U
1,500 ft (457 m)
*Cable requirements:
75-ohm impedance
All-copper center conductor
All-copper braided shield with 95% braid coverage