Case 1. Starting failure 
CHECK
PROBABLE CAUSES
ACTION
fuel tank
incorrect fuel
drain it and with correct fuel
fuel filter
fuel filter is clogged
clean
carburetor adjustment screw
out of normal range
adjust to normal range
sparking (no spark)
spark plug is fouled/wet
clean/dry
plug gap is incorrect
correct (GAP: 0.6 – 0.7 mm)
spark plug
disconnected
retighten
Case 2. Engine starts but does not keep running/Hard re-starting.
CHECK
PROBABLE CAUSES
ACTION
fuel tank
incorrect fuel or staled fuel
drain it and with correct fuel
carburetor adjustment screw
out of normal range
adjust to normal range
muffler,cylinder (exhaust port)
carbon is built-up
wipe away
air cleaner
clogged with dust
wash
cylinder fin, fan cover
clogged with dust
clean
When your unit seems to need further service, please consult with our service shop in your area. 
English
10. Troubleshooting guide
Français
10. Guide de localisation des pannes
1er cas : Défaut de démarrage
VERIFICATION
CAUSES PROBABLES
ACTION
réservoir de carburant
carburant incorrect
vidanger et remplacer le carburant
filtre à carburant
filtre à carburant colmaté
nettoyer
vis de réglage de carburateur
déréglé
refaire le réglage
allumage
bougie sale ou noyée
nettoyer ou sécher
Jeu d’électrodes incorrect
régler le jeu (de 0,6 à 0,7 mm)
Bougie d’allumage
débrancher
resserrer
2ème cas : Le moteur démarre mais ne reste pas en marche ou est difficile à redémarrer
VERIFICATION
CAUSES PROBABLES
ACTION
réservoir de carburant
carburant incorrect
vidanger et remplacer le carburant
vis de réglage de carburateur
déréglé
refaire le réglage
silencieux, cylindre
dépôt de calamine
retirer
filtre à air
colmaté de poussière
nettoyer
ailette de cylindre/flasque de ventilateur
colmaté  de poussière
nettoyer
Si la machine nécessite des opérations d’entretien plus élaborées, contacter le centre de service après-vente le plus proche.