Zenoah BC2000 Manuel D’Utilisation
48
Case 1. Starting failure
CHECK
PROBABLE CAUSES
ACTION
fuel tank
➞
incorrect fuel
➞
drain it and with correct fuel
fuel filter
➞
fuel filter is clogged
➞
clean
carburetor adjustment screw
➞
out of normal range
➞
adjust to normal range
sparking (no spark)
➞
spark plug is fouled/wet
➞
clean/dry
➞
plug gap is incorrect
➞
correct (GAP: 0.6 – 0.7 mm)
spark plug
➞
disconnected
➞
retighten
Case 2. Engine starts but does not keep running/Hard re-starting.
CHECK
PROBABLE CAUSES
ACTION
fuel tank
➞
incorrect fuel or staled fuel
➞
drain it and with correct fuel
carburetor adjustment screw
➞
out of normal range
➞
adjust to normal range
muffler,cylinder (exhaust port)
➞
carbon is built-up
➞
wipe away
air cleaner
➞
clogged with dust
➞
wash
cylinder fin, fan cover
➞
clogged with dust
➞
clean
When your unit seems to need further service, please consult with our service shop in your area.
English
10. Troubleshooting guide
Français
10. Guide de localisation des pannes
1er cas : Défaut de démarrage
VERIFICATION
CAUSES PROBABLES
ACTION
réservoir de carburant
➞
carburant incorrect
➞
vidanger et remplacer le carburant
filtre à carburant
➞
filtre à carburant colmaté
➞
nettoyer
vis de réglage de carburateur
➞
déréglé
➞
refaire le réglage
allumage
➞
bougie sale ou noyée
➞
nettoyer ou sécher
➞
Jeu d’électrodes incorrect
➞
régler le jeu (de 0,6 à 0,7 mm)
Bougie d’allumage
➞
débrancher
➞
resserrer
2ème cas : Le moteur démarre mais ne reste pas en marche ou est difficile à redémarrer
VERIFICATION
CAUSES PROBABLES
ACTION
réservoir de carburant
➞
carburant incorrect
➞
vidanger et remplacer le carburant
vis de réglage de carburateur
➞
déréglé
➞
refaire le réglage
silencieux, cylindre
➞
dépôt de calamine
➞
retirer
filtre à air
➞
colmaté de poussière
➞
nettoyer
ailette de cylindre/flasque de ventilateur
➞
colmaté de poussière
➞
nettoyer