OPERATION
APPLYING POWER
1.  Connect the AC power cable to the 120 VAC receptacle 
on the generator used. See Figure 13.
Figure 13. Connecting to Power Source
2.  Start the generator as indicated in the generator 
manual.
3.  Turn on the power of the generator. The balloon will 
start to inflate and the lamp will turn on. at 200 W.
DIMMING THE LAMP
1.  Press the dimmer switch to control the brightness of 
the lamp (Figure 14). The lamp can be turned off or 
set to 100W, 200W, 300W. The corresponding LED will 
light red when selected (Figure 15).
Figure 14. Dimmer Switch
Figure 15. Brightness LED Indicators
20A
120V
120 VAC
RECEPTACLE
POWER
CABLE
TYPICAL
GENERATOR
FRONT PANEL
DIMMER
SWITCH
2.  Zip up the bottom of the balloon completely after use 
of the dimmer switch.
SILENT MODE
Noise coming from the unit during operation can be 
eliminated.
1.  Press and hold the dimmer switch (Figure 14) for 2 
seconds. The blue LED in the center of the switch will 
flash when in silent mode.
2.  To switch back to normal mode, press and hold the 
dimmer switch for 3 seconds. The blue LED will stop 
flashing.
SHUTDOWN
1.  Turn off the power switch of the generator. The balloon 
should start to deflate and the lamp will turn off.
2.  Disconnect the AC power cable from the generator.
 NOTICE
The brightness of the lamp can still be adjusted when 
in silent mode.
When unit is restarted, it will revert to normal mode 
even if silent mode was selected prior to shutdown.