Multiquip GB3LED Manuel D’Utilisation

Page de 38
GB3LED LIGHTING SYSTEM • OPERATION AND PARTS MANUAL — REV. #0 (03/18/14)  — PAGE 25
TROUBLESHOOTING
Troubleshooting
Symptom
Possible Problem
Solution
Lamp does not light.
Is plug connected?
Plug in correctly.
Is generator’s main switch turned off? Turn on switch.
Are any wire cables disconnected?
Connect disconnected wire cable.
Are any other electric appliances 
(other than light tower) plugged into 
power source?
Unplug all other appliances.
Is generator voltage not normal 
(standby voltage - 100 ± 5 V)?
Use proper voltage.
Balloon is not infl ating.
Is zipper unzipped?
Zip balloon completely.
Is fan motor not properly operating?
Inspect and repair fan motor if 
necessary.
Is balloon torn?
Repair balloon.